The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Optimal signal bandwidth for the recording of surface EMG activity of facial, jaw, oral, and neck muscles
Abstract
Spontaneous pericranial electromyographic (EMG) activity is generally small and is contaminated by strong low-frequency artifacts. High-pass filtering should suppress artifacts but affect EMG signal power only minimally. In 24 subjects who performed a warned simple reaction time task, the optimal high-pass cut-off frequency was examined for nine different pericranial muscles. From four experimental conditions (visual and auditory reaction signals combined with hand and foot responses), 1-min EMG recordings were selected (bandwidth: 0.4-512 Hz) and divided into 60 1-s data segments. These segments were high-pass filtered, the -3-dB cut-off frequency varying from 5 to 90 Hz, and subjected to power spectral analysis. Optimal high-pass filter frequencies were determined for the mean power spectra based on visual estimation or comparison with a theoretical spectrum of the artifact-free EMG signal. The optimal frequencies for the different muscles varied between 15 and 25 Hz and were not influenced by stimulus or response modality. For all muscles, a low-pass filter frequency between 400 and 500 Hz was appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Guidelines for Human Electromyographic Research
Fridlund, A. J., & Cacioppo, J. T. (1986) · Psychophysiology · doi:10.1111/j.1469-8986.1986.tb00676.x · Cited by 1,737
Myoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 1,097
Models of recruitment and rate coding organization in motor-unit pools.
Fuglevand, A. J., Winter, D. A., & Patla, A. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.6.2470 · Cited by 988
Motor Units: Anatomy, Physiology, and Functional Organization
Burke, R. E. (1981) · Comprehensive Physiology · doi:10.1002/cphy.cp010210 · Cited by 782
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
(1973) · Applied Acoustics · doi:10.1016/0003-682x(73)90017-0 · Cited by 443
Digital Filtering: Background and Tutorial for Psychophysiologists
Cook, E. W., & Miller, G. A. (1992) · Psychophysiology · doi:10.1111/j.1469-8986.1992.tb01709.x · Cited by 187
A Nonstationary Model for the Electromyogram
Shwedyk, E., Balasubramanian, R., & Scott, R. N. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326175 · Cited by 169
Boxtel, A. V., & Jessurun, M. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02085.x · Cited by 159
Effect of motor-unit firing time statistics on e.m.g. spectra
Lago, P. J. A., & Jones, N. B. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457923 · Cited by 122
Activity Patterns of Human Skeletal Muscles: Relation to Muscle Fiber Type Composition
Monster, A. W., Chan, H. C., & O'Connor, D. (1978) · Science · doi:10.1126/science.635587 · Cited by 120
Waterink, W., & Boxtel, A. V. (1994) · Biological Psychology · doi:10.1016/0301-0511(94)90001-9 · Cited by 109
Changes in electromyogram power spectra of facial and jaw-elevator muscles during fatigue
Boxtel, A. V., Goudswaard, P., van der Molen, G. M., & Bosch, W. E. J. V. D. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.1.51 · Cited by 104
Boxtel, A. V., Boelhouwer, A. J. W., & BOS, A. R. (1998) · Psychophysiology · doi:10.1017/s0048577298970317 · Cited by 104
Krogh-Lund, C., & J�rgensen, K. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00760803 · Cited by 92
Krogh-Lund, C., & J�rgensen, K. (1993) · European Journal of Applied Physiology · doi:10.1007/bf01427058 · Cited by 89
The Size Principle: Still Working After All These Years
Cope, T., & PINTER, M. (1995) · Physiology · doi:10.1152/physiologyonline.1995.10.6.280 · Cited by 72
Daily durations of spontaneous activity in cat’s ankle muscles
Hensbergen, E., & Kernell, D. (1997) · Experimental Brain Research · doi:10.1007/pl00005701 · Cited by 66
Motor Unit Firing Rate During Static Contraction Indicated by the Surface EMG Power Spectrum
Boxtel, A. V., & Schomaker, L. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325057 · Cited by 64
Influence of motor unit firing statistics on the median frequency of the EMG power spectrum
Boxtel, A. V., & Schomaker, L. (1984) · European Journal of Applied Physiology · doi:10.1007/bf00433394 · Cited by 58
Effect of bite force on the power spectrum of the surface electromyogram of human jaw muscles
Palla, S., & Ash, M. M. (1981) · Archives of Oral Biology · doi:10.1016/0003-9969(81)90049-2 · Cited by 56
Motor unit power spectrum and firing rate
Pan, Z. S., Zhang, Y., & Parker, P. A. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442164 · Cited by 48
Amplitude and Bandwidth of the Frontalis Surface EMG: Effects of Electrode Parameters
Boxtel, A. V., Goudswaard, P., & Schomaker, L. (1984) · Psychophysiology · doi:10.1111/j.1469-8986.1984.tb00260.x · Cited by 32
Single motor unit myoelectric signal analysis with nonstationary data
Englehart, K. B., & Parker, P. A. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284928 · Cited by 28
Non-invasive electromyography of human genioglossal (tongue) activity.
Sauerland, E. K., Ba, S., Wc, O., et al. (1981) · PubMed · Cited by 27
Boxtel, A. V., Damen, E. J. P., & BRUNIA, C. H. M. (1996) · Psychophysiology · doi:10.1111/j.1469-8986.1996.tb02434.x · Cited by 20
Functioning of the ensemble of motor units of the muscle determined from global EMG signal.
Verroust, J., Blinowska, A., & Cannet, G. (1981) · PubMed · Cited by 11
Svebak, S., Braathen, E. T., Sejersted, O. M., Bowim, B., Fauske, S., & Laberg, J. C. (1993) · International Journal of Psychophysiology · doi:10.1016/0167-8760(93)90094-6 · Cited by 10
Cited by
Filtering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Highly Stretchable, Elastic, and Ionic Conductive Hydrogel for Artificial Soft Electronics
Zhou, Y., Wan, C., Yang, Y., Yang, H., Wang, S., Dai, Z., Ji, K., Jiang, H., Chen, X., & Long, Y. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806220 · Cited by 933
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Cardiovascular, electrodermal, and respiratory response patterns to fear‐ and sadness‐inducing films
Kreibig, S. D., Wilhelm, F. H., Roth, W. T., & Gross, J. J. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00550.x · Cited by 495
Metadata
- Authors
- VAN BOXTEL, A.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 38
- Issue
- 1
- Pages
- 22-34
- ISSN
- 0048-5772 (ISSN-L)
- OpenAlex
- W2101988387
- Cited by
- 292
- References
- 33
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.