Macaque vision after magnocellular lateral geniculate lesions
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Ibotenic-acid lesions of the magnocelluar portion of the macaque lateral geniculate nucleus were used to examine the role of the M-cell pathway in spatio-temporal contrast sensitivity. A lesion was place in layer 1 of the lateral geniculate of each of two monkeys. Physiological mapping in one animal demonstrated that the visual-field locus of the lesion was on the horizontal meridian, approximately 6 deg in the temporal field. Visual thresholds were tested monocularly in the contralateral eye, and fixation locus was monitored with a scleral search coil to control the retinal location of the test target. Three threshold measures were clearly disrupted by the magnocellular lesions. Contrast sensitivity for a 1 cycle/deg grating that drifted at 10 Hz was reduced from about twofold greater than, to about the same as, that for 10-Hz counterphase modulated gratings. Sensitivity for a very low spatial frequency (Gaussian blob), 10-Hz flickering stimulus was reduced so severely that no threshold could be measured. In addition, flicker resolution was greatly reduced at lower modulation depths (0.22), but not at higher depths (1.0). Two of the measured thresholds were unaffected by the lesions. Contrast sensitivity for 2 cycle/deg stationary gratings remained intact, and little or no effect on sensitivity was found for 1 cycle/deg, 10-Hz counterphase modulated gratings. Together, these results suggest that the magnocellular pathway makes little contribution to visual sensitivity at low to moderate temporal frequencies. On the other hand, some contribution to detection sensitivity is evident at lower spatial and high temporal frequencies, especially for drifting stimuli. It appears that a major role of the magnocellular pathway may be to provide input to cortical mechanisms sensitive to rapid visual motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Investigative Ophthalmology and Visual Science
Frey, C. (2010) · Cited by 3,350
Wong-Riley, M. (1979) · Brain Research · doi:10.1016/0006-8993(79)90728-5 · Cited by 1,858
Chromatic mechanisms in lateral geniculate nucleus of macaque.
Derrington, A. M., Krauskopf, J., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015499 · Cited by 1,608
Implantation of magnetic search coils for measurement of eye position: An improved method
Judge, S. J., Richmond, B. J., & Chu, F. C. (1980) · Vision Research · doi:10.1016/0042-6989(80)90128-5 · Cited by 1,536
Visual Processing in Monkey Extrastriate Cortex
Maunsell, J. H. R., & Newsome, W. T. (1987) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.10.030187.002051 · Cited by 1,135
Self-citationSpatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.
Derrington, A. M., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015498 · Cited by 1,058
Retinal ganglion cells that project to the dorsal lateral geniculate nucleus in the macaque monkey
Perry, V. H., Oehler, R., & Cowey, A. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90006-x · Cited by 717
Newsome, W., Wurtz, R., Dursteler, M., & Mikami, A. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-03-00825.1985 · Cited by 670
de Lange Dzn, H. (1958) · Journal of the Optical Society of America · doi:10.1364/josa.48.000777 · Cited by 596
Cat and monkey retinal ganglion cells and their visual functional roles
Shapley, R., & Hugh Perry, V. (1986) · Trends in Neurosciences · doi:10.1016/0166-2236(86)90064-0 · Cited by 588
Ibotenic acid-induced neuronal degeneration: A morphological and neurochemical study
Schwarcz, R., H�kfelt, T., Fuxe, K., Jonsson, G., Goldstein, M., & Terenius, L. (1979) · Experimental Brain Research · doi:10.1007/bf00237708 · Cited by 462
Functions of the colour-opponent and broad-band channels of the visual system
Schiller, P. H., Logothetis, N. K., & Charles, E. R. (1990) · Nature · doi:10.1038/343068a0 · Cited by 417
Sensitivity of macaque retinal ganglion cells to chromatic and luminance flicker.
Lee, B. B., Martin, P. R., & Valberg, A. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017685 · Cited by 310
Purpura, K., Tranchina, D., Kaplan, E., & Shapley, R. M. (1990) · Visual Neuroscience · doi:10.1017/s0952523800002789 · Cited by 199
Spatio-temporal vision of macaques with severe loss of Pβ retinal ganglion cells
Merigan, W. H., & Eskin, T. A. (1986) · Vision Research · doi:10.1016/0042-6989(86)90125-2 · Cited by 193
Self-citationSummation and discrimination of gratings moving in opposite directions
Watson, A. B., Thompson, P. G., Murphy, B. J., & Nachmias, J. (1980) · Vision Research · doi:10.1016/0042-6989(80)90020-6 · Cited by 178
Chromatic and achromatic vision of macaques: role of the P pathway
Merigan, W. (1989) · The Journal of Neuroscience · doi:10.1523/jneurosci.09-03-00776.1989 · Cited by 171
Self-citationA three channel model of temporal frequency perception
Mandler, M. B., & Makous, W. L. (1984) · Vision Research · doi:10.1016/0042-6989(84)90021-x · Cited by 129
Extrageniculostriate vision in the monkey. VII. Contrast sensitivity functions
Miller, M., Pasik, P., & Pasik, T. (1980) · Journal of Neurophysiology · doi:10.1152/jn.1980.43.6.1510 · Cited by 89
A model for direction selectivity in threshold motion perception
Wilson, H. R. (1985) · Biological Cybernetics · doi:10.1007/bf00337147 · Cited by 65
Temporal modulation sensitivity of macaque monkeys
Merigan, W. H. (1980) · Vision Research · doi:10.1016/0042-6989(80)90077-2 · Cited by 29
Self-citationThe role of cortical directional selectivity in detection of motion and flicker
Pasternak, T. (1986) · Vision Research · doi:10.1016/0042-6989(86)90100-8 · Cited by 15
Cited by
How parallel are the primate visual pathways?
Merigan, W. H., & Maunsell, J. H. R. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002101 · Cited by 1,597
Self-citationBertone, A., Mottron, L., Jelenic, P., & Faubert, J. (2005) · Brain · doi:10.1093/brain/awh561 · Cited by 536
Receptive fields of P and M ganglion cells across the primate retina
Croner, L. J., & Kaplan, E. (1995) · Vision Research · doi:10.1016/0042-6989(94)e0066-t · Cited by 492
Neural bases of visual deficits during aging
Spear, P. D. (1993) · Vision Research · doi:10.1016/0042-6989(93)90218-l · Cited by 406
The magnocellular deficit theory of dyslexia: the evidence from contrast sensitivity
Skottun, B. C. (2000) · Vision Research · doi:10.1016/s0042-6989(99)00170-4 · Cited by 397
Metadata
- Authors
- Merigan, W. H., & Maunsell, J. H. R.
- Venue
- Visual Neuroscience
- Publisher
- Maximum Academic Press
- Published
- 1990-10
- Volume
- 5
- Issue
- 04
- Pages
- 347-352
- ISSN
- 0952-5238 (ISSN-L)
- 1469-8714
- OpenAlex
- W2076153062
- Cited by
- 277
- References
- 22
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.