Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,058

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.

Open access
Derrington, A M, Lennie, P·1984·The Journal of Physiology

Abstract

The discharges of single neurones in the parvocellular and magnocellular laminae of the macaque's lateral geniculate nucleus (l.g.n.) were recorded with glass‐insulated tungsten micro‐electrodes. Linearity of spatial summation was examined using the test devised by Hochstein & Shapley (1976). 2 of 272 parvocellular units and 6 of 105 magnocellular units showed clearly non‐linear spatial summation. A quantitative index of non‐linearity did not suggest the existence of a distinct 'non‐linear' class of magnocellular unit. Spatial contrast sensitivity to moving gratings was measured by a tracking procedure in which contrast was adjusted to elicit a reliable modulation of discharge. With the exception of cells that were driven by blue‐sensitive cones, measurements of contrast sensitivity did not reveal distinct subgroups of parvocellular units. All had low sensitivity, and those with receptive fields in the fovea could resolve spatial frequencies of up to 40 cycles deg‐1. Magnocellular units had substantially higher sensitivity, but poorer spatial resolution. The higher sensitivities of magnocellular units led to their giving saturated responses to stimuli of high contrast. Responses of parvocellular units were rarely saturated by any stimulus. At any one eccentricity the receptive fields of parvocellular units had smaller centres than did those of magnocellular units. Receptive fields of magnocellular units driven by the ipsilateral eye had larger receptive fields than did those driven by the contralateral eye. Parvocellular units were most sensitive to stimuli modulated at temporal frequencies close to 10 Hz; magnocellular units to stimuli modulated at frequencies nearer 20 Hz. The loss of sensitivity as temporal frequency fell below optimum was more marked in magnocellular than parvocellular units. Changes in temporal frequency altered the shapes of the spatial contrast sensitivity curves of both parvocellular and magnocellular units. These changes could be explained by supposing that centre and surround have different temporal properties, and that the surround is relatively less sensitive to higher temporal frequencies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1984.sp015498

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,058

Metadata

Authors
Derrington, A. M., & Lennie, P.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1984-12
Volume
357
Issue
1
Pages
219-240
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1996822428
Cited by
1,058
References
1
FWCI
6.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015498
The paper
Derrington, A. M., & Lennie, P. (1984). Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015498

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.