Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring

Ballerstadt, Ralph, Schultz, Jerome S.·2000·Analytical Chemistry

Abstract

A novel concept of a fluorescence affinity hollow fiber sensor for transdermal glucose monitoring is demonstrated. The glucose-sensing principle is based on the competitive reversible binding of a mobile fluorophore-labeled Concanavalin A (Con A) to immobile pendant glucose moites inside of intensely colored Sephadex beads. The highly porous beads (molecular weight cutoff of 200 kDa) were colored with two red dyes, Safranin O and Pararosanilin, selected to block the excitation and spectrum of the fluorophore Alexa488. The sensor consists of the dyed beads and Alexa488-Con A confined inside a sealed, small segment of a hollow fiber dialysis membrane (diameter 0.5 mm, length 0.5 cm, molecular weight cutoff 10 kDa). In the absence of glucose, the majority of Alexa488-Con A resides inside the colored beads bound to fixed glucose. Thus, excitation light at 490 nm impinging on the sensor is strongly absorbed by the dyes, resulting in a drastically reduced fluorescence emission at 520 nm from the Alexa488-Con A residing within the beads. However, when the hollow fiber sensor is exposed to glucose, glucose diffuses through the membrane into the sensor chamber and competitively displaces Alexa 488-Con A molecules from the glucose residues of the Sephadex beads. Thus, Alexa 488-Con A appears in the void space outside of the beads and is fully exposed to the excitation light, and a strong increase in fluorescence emission at 520 nm is measured. At a medium to high loading degree of Sephadex with Alexa488-Con A (10 mg mL(-1) bead suspension), the absolute fluorescence increase due to 20 mM glucose was very large. It exceeded the response of other sensor devices based on FRET by a factor of 50 (Meadows and Schultz Anal. Chim. Acta 1993, 280, 21-30; Russell et al. Anal. Chem. 1999, 71, 3126-3132). The new sensor featured a glucose detection range extending from 0.15 to 100 mM, exhibiting the strongest dynamic signal change from 0.2 to 30 mM. It showed a reasonably fast response time (4-5 min). The combination of all the beneficial sensor features makes this sensor extremely attractive for future in vivo implantation studies for glucose monitoring in subdermal tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac000215r

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Ballerstadt, R., & Schultz, J. S.
Venue
Analytical Chemistry
Published
2000-08-08
Volume
72
Issue
17
Pages
4185-4192
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2023587387
Cited by
192
References
0
FWCI
5.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring. https://app.cochat.ai/papers/10.1021/ac000215r
The paper
Ballerstadt, R., & Schultz, J. S. (2000). A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring. Analytical Chemistry. https://doi.org/10.1021/ac000215r

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.