The DOI matches its Crossref record.
High-performance capillary electrophoresis of SDS-protein complexes using UV-transparent polymer networks
Abstract
This paper demonstrates the use of UV-transparent replaceable polymer networks for the separation of SDS-protein complexes on the basis of molecular weight. First, the use of linear (i.e. non-cross-linked) polyacrylamide is shown to provide molecular separation of SDS-protein complexes. A study reveals such columns to yield significantly greater lifetime than cross-linked gels because of the flexibility of the noncovalently attached polymer chains. However, column lifetime was still found to be limited (approximately 20-40 injections), and detection at 214 nm was problematical because of the absorbance of polyacrylamide. UV-transparent polymer networks of dextran and PEG were substituted for polyacrylamide with successful molecular weight sieving of SDS-protein complexes at 214 nm. Due to their low to moderate viscosities, these networks could be routinely replaced leading to the possibility of hundreds of injections with a single column. Migration time reproducibilities of 0.5% RSD or less were found with replacement of the network. Using dextran, calibration plots of peak area vs concentration of standard protein were linear over the range of 0.5 microgram/mL up to at least 0.25 mg/mL. Furthermore, plasma samples could be directly utilized because of the strong solvating power of SDS. Rapid separation of protein mixtures are demonstrated with these UV-transparent polymer networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001) · Analytical Chemistry · doi:10.1021/ac0012492 · Cited by 283
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202
Metadata
- Authors
- Ganzler, K., Greve, K. S., Cohen, A. S., Karger, B. L., Guttman, A., & Cooke, N. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1992-11-15
- Volume
- 64
- Issue
- 22
- Pages
- 2665-2671
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2084471305
- Cited by
- 242
- References
- 0
- FWCI
- 24.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-performance capillary electrophoresis of SDS-protein complexes using UV-transparent polymer networks. https://app.cochat.ai/papers/10.1021/ac00046a003
- The paper
- Ganzler, K., Greve, K. S., Cohen, A. S., Karger, B. L., Guttman, A., & Cooke, N. C. (1992). High-performance capillary electrophoresis of SDS-protein complexes using UV-transparent polymer networks. Analytical Chemistry. https://doi.org/10.1021/ac00046a003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.