The DOI matches its Crossref record.
Microchip Devices for High-Efficiency Separations
Abstract
We have fabricated a 25-cm-long spiral-shaped separation channel on a glass microchip with a footprint of only 5 cm x 5 cm. Electrophoretic separation efficiencies for dichlorofluoroscein (DCF) on this chip exceeded 1,000,000 theoretical plates and were achieved in under 46 s at a detection point 22.2 cm from the injection cross. The number of theoretical plates increased linearly with the applied voltage, and at a separation field strength of 1,170 V/cm, the rate of plate generation was approximately 21,000 plates/s. The large radii of curvature of the turns minimized the analyte dispersion introduced by the channel geometry as evidenced by the fact that the effective diffusion coefficient of DCF was within a few percent of that measured on a microchip with a straight separation channel over a wide range of electric field strengths. A micellar electrokinetic chromatography separation of 19 tetramethylrhodamine-labeled amino acids was accomplished in 165 s with an average plate number of 280,000. The minimum resolution between adjacent peaks for this separation was 1.2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Self-citationMicrofluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/ac503964j · Cited by 136
Self-citation
Metadata
- Authors
- Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-10-26
- Volume
- 72
- Issue
- 23
- Pages
- 5814-5819
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2054550547
- Cited by
- 185
- References
- 0
- FWCI
- 12.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microchip Devices for High-Efficiency Separations. https://app.cochat.ai/papers/10.1021/ac0006268
- The paper
- Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2000). Microchip Devices for High-Efficiency Separations. Analytical Chemistry. https://doi.org/10.1021/ac0006268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.