The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Glucose electrodes based on cross-linked bis(2,2'-bipyridine)chloroosmium(+/2+) complexed poly(1-vinylimidazole) films
Abstract
Enzyme electrodes based on a redox hydrogel formed upon complexing water-soluble poly(1-vinylimidazole) (PVI) with [Os(bpy)2Cl]+ and cross-linked with water-soluble poly(ethylene glycol) diglycidyl ether (molecular weight 400, peg 400) are described. The properties of the electrodes depended on their polymers' osmium content, the extent of cross-linking, the pH, and the ionic strength in which they were used. The redox hydrogels' electron diffusion coefficients (De) increased with osmium content of their polymers. The De values were 1.5 x 10(-8), 1.3 x 10(-8), and 4.3 x 10(-9) cm2/s for PVI3-Os, PVI5-Os, and PVI10-Os, respectively, the subscripts indicating the number of monomer units per osmium redox center. De decreased with increasing ionic strength and increased upon protonation of the polymer. In glucose electrodes, made by incorporating into their films glucose oxidase (GOX) through covalent bonding in the cross-linking step, glucose was electrooxidized at > 150 mV (SCE). The characteristics of these electrodes depended on the GOX concentration, film thickness, O2 concentration, pH, NaCl concentration, and electrode potential. The steady-state glucose electrooxidation currents were independent of the polymers' osmium content in the studied (3-10 monomer units per osmium center) range. Electrodes containing 39% GOX reached steady-state glucose electrooxidation current densities of 400 microA/cm2 and, when made with thick gel films, were selective for glucose in the presence of physiological concentrations of ascorbate and acetaminophen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical connection of enzyme redox centers to electrodes
Heller, A. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100188a007 · Cited by 603
Self-citationDegani, Y., & Heller, A. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00188a091 · Cited by 354
Self-citationGregg, B. A., & Heller, A. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a046 · Cited by 275
Self-citationForster, R. J., & Vos, J. G. (1990) · Macromolecules · doi:10.1021/ma00222a008 · Cited by 230
Elimination of electrooxidizable interferant-produced currents in amperometric biosensors
Maidan, R., & Heller, A. (1992) · Analytical Chemistry · doi:10.1021/ac00047a003 · Cited by 117
Self-citation
Cited by
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
Enzymatic reactions in confined environments
Küchler, A., Yoshimoto, M., Luginbühl, S., Mavelli, F., & Walde, P. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.54 · Cited by 733
Ohara, T. J., Rajagopalan, R., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00087a008 · Cited by 379
Self-citationEmerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citation
Metadata
- Authors
- Ohara, T. J., Rajagopalan, R., & Heller, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-12-01
- Volume
- 65
- Issue
- 23
- Pages
- 3512-3517
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1769550528
- Cited by
- 281
- References
- 5
- FWCI
- 12.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.