Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Electrochemistry in Diabetes Management

Heller, Adam, Feldman, Ben·2010·Accounts of Chemical Research

Abstract

Diabetes devastates lives and burdens society. Hypoglycemic (low glucose) episodes cause blackouts, and severe ones are life-threatening. Periods of hyperglycemia (high glucose) cause circulatory disease, stroke, amputations, blindness, kidney failure and nerve degeneration. In this Account, we describe the founding of TheraSense, now a major part of Abbott Diabetes Care, and the development of two products that have improved the lives of people with diabetes. The first, a virtually painless microcoulometer (300 nL volume), the FreeStyle blood glucose monitoring system, was approved by the FDA and became available in 2000. In 2009, this system was used in more than one billion blood assays. The second, the enzyme-wiring based, subcutaneously-implanted FreeStyle Navigator continuous glucose monitoring system, was approved by the FDA and became available in the United States in 2008. The strips of the FreeStyle blood glucose monitoring system comprise a printed parallel plate coulometer, with a 50 microm gap between two facing printed electrodes, a carbon electrode and a Ag/AgCl electrode. The volume of blood between the facing plates is accurately controlled. The glucose is electrooxidized through catalysis by a glucose dehydrogenase (GDH) and an Os(2+/3+) redox mediator, which is reduced by the glucose-reduced enzyme and is electrooxidized on the carbon electrode. Initially the system used pyrroloquinoline quinone (PQQ)-dependent GDH but now uses flavin adenine dinucleotide (FAD)-dependent GDH. Because the facing electrodes are separated by such a small distance, shuttling of electrons by the redox couple could interfere with the coulometric assay. However, the Os(2+/3+) redox mediator is selected to have a substantially negative formal potential, between 0.0 and -0.2 V, versus that of the facing Ag/AgCl electrode. This makes the flow of a shuttling current between the two electrodes virtually impossible because the oxidized Os(3+) complex cannot be appreciably reduced at the more positively poised Ag/AgCl electrode. The FreeStyle Navigator continuous glucose monitoring system uses a subcutaneously implanted miniature plastic sensor connected to a transmitter to measure glycemia amperometrically and sends the information to a PDA-like device every minute. The sensor consists of a narrow (0.6 mm wide) plastic substrate on which carbon-working, Ag/AgCl reference, and carbon counter electrodes are printed in a stacked geometry. The active wired enzyme sensing layer covers only about 0.1 mm(2) of the working electrode and is overlaid by a flux-limiting membrane. It resides at about 5 mm depth in the subcutaneous adipose tissue and monitors glucose concentrations over the range 20-500 mg/dL. Its core component, a miniature, disposable, amperometric glucose sensor, has an electrooxidation catalyst made from a crosslinked adduct of glucose oxidase (GOx) and a GOx wiring redox hydrogel containing a polymer-bound Os(2+/3+) complex. Because of the selectivity of the catalyst for glucose, very little current flows in the absence of glucose. That feature, either alone or in combination with other features of the sensor, facilitates the one-point calibration of the system. The sensor is implanted subcutaneously and replaced by the patient after 5 days use with minimal pain. The wearer does not feel its presence under the skin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ar9002015

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 2

  1. Gregg B. A., 1991, J. Phys. Chem., 95, 5976, 10.1021/j100168a047 · doi:10.1021/j100168a047
  2. Quinn C. P., 1995, Am. J. Physiol., 269, E155

Cited by

See all 255

Metadata

Authors
Heller, A., & Feldman, B.
Venue
Accounts of Chemical Research
Published
2010-04-12
Volume
43
Issue
7
Pages
963-973
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W2081832007
Cited by
255
References
34
FWCI
16.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemistry in Diabetes Management. https://app.cochat.ai/papers/10.1021/ar9002015
The paper
Heller, A., & Feldman, B. (2010). Electrochemistry in Diabetes Management. Accounts of Chemical Research. https://doi.org/10.1021/ar9002015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.