The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
An Electrochemical Metalloimmunoassay Based on a Colloidal Gold Label
Abstract
A novel, sensitive electrochemical immunoassay has been developed using a colloidal gold label that, after oxidative gold metal dissolution in an acidic solution, was indirectly determined by anodic stripping voltammetry (ASV) at a single-use carbon-based screen-printed electrode (SPE). The use of disposable electrodes allows for simplified measurement in 35 microL of solution. The method was evaluated for a noncompetitive heterogeneous immunoassay of an immunoglobulin G (IgG) and a concentration as low as 3 x 10(-12) M was determined, which is competitive with colorimetric ELISA or with immunoassays based on fluorescent europium chelate labels. The high performance of the method is related to the sensitive ASV determination of gold(III) at a SPE (detection limit of 5 x 10(-9) M) and to the release of a large number of gold(III) ions from each gold particle anchored on the immunocomplex (e.g., 1.7 x 10(5) gold atoms are theoretically contained in a 18-nm spherical gold particle).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Preparation and Characterization of Au Colloid Monolayers
Grabar, K. C., Freeman, R. G., Hommer, M. B., & Natan, M. J. (1995) · Analytical Chemistry · doi:10.1021/ac00100a008 · Cited by 2,756
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Colloidal Au-Enhanced Surface Plasmon Resonance Immunosensing
Lyon, L. A., Musick, M. D., & Natan, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac9809940 · Cited by 618
Hendrickson, W. A., Pähler, A., Smith, J. L., Satow, Y., Merritt, E. A., & Phizackerley, R. P. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.7.2190 · Cited by 588
Blackburn, G. F., Shah, H. P., Kenten, J. H., Leland, J., Kamin, R. A., Link, J., Peterman, J., Powell, M. J., Shah, A., & Talley, D. B. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1534 · Cited by 558
Immunolabeling for Electron Microscopy
Sarraf, C. E. (2000) · Methods in Molecular Medicine · doi:10.1385/1-59259-076-4:439 · Cited by 217
Volpe, G., Draisci, R., Palleschi, G., & Compagnone, D. (1998) · The Analyst · doi:10.1039/a800255j · Cited by 175
García, M. B. G., & Garcı́a, A. C. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01813-t · Cited by 119
Bersier, P. M., Howell, J. O., & Bruntlett, C. S. (1994) · The Analyst · doi:10.1039/an9941900219 · Cited by 109
Sato, H., Mizutani, S., Tsuge, S., Ohtani, H., Aoi, K., Takasu, A., Okada, M., Kobayashi, S., Kiyosada, T., & Shoda, S. (1998) · Analytical Chemistry · doi:10.1021/ac9706685 · Cited by 98
Varenne, A., Vessières, A., Salmain, M., Durand, S., Brossier, P., & Jaouen, G. (1996) · Analytical Biochemistry · doi:10.1006/abio.1996.0450 · Cited by 49
Spectroscopic and photochemical properties of methyl thionitrite (CH3SNO)
Niki, H., Maker, P. D., Savage, C. M., & Breitenbach, L. P. (1983) · The Journal of Physical Chemistry · doi:10.1021/j100224a003 · Cited by 31
Turyan, I., & Mandler, D. (1993) · Analytical Chemistry · doi:10.1021/ac00063a026 · Cited by 30
The determination of gold by anodic stripping voltammetry
Lintern, M. J., Mann, A. W., & Longman, D. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)84562-6 · Cited by 26
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Noble Metal Nanoparticles for Biosensing Applications
Doria, G., Conde, J., Veigas, B., Giestas, L., Almeida, C., Assunção, M., Rosa, J., & Baptista, P. V. (2012) · Sensors · doi:10.3390/s120201657 · Cited by 708
Metadata
- Authors
- Dequaire, M., Degrand, C., & Limoges, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-10-21
- Volume
- 72
- Issue
- 22
- Pages
- 5521-5528
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2013113223
- Cited by
- 379
- References
- 15
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.