The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Subsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes
Abstract
High-repetition fast-scan cyclic voltammetry and chronoamperometry were used to quantify and characterize the kinetics of dopamine and dopamine-o-quinone adsorption and desorption at carbon-fiber microelectrodes. A flow injection analysis system was used for the precise introduction and removal of a bolus of electroactive substance on a sub-second time scale to the disk-shaped surface of a microelectrode that was fabricated from a single carbon fiber (Thornel type T650 or P55). Pretreatment of the electrode surfaces consisted of soaking them in purified isopropyl alcohol for a minimum of 10 min, which resulted in S/N increasing by 200-400% for dopamine above that for those that were soaked in reagent grade solvent. Because of adsorption, high scan rates (2,000 V/s) are shown to exhibit equivalent S/N ratios as compared to slower, more traditional scan rates. In addition, the steady-state response to a concentration bolus is shown to occur more rapidly when cyclic voltammetric scans are repeated at short intervals (4 ms). The new methodologies allow for more accurate determinations of the kinetics of neurotransmitter release events (10-500 ms) in biological systems. Brain slice and in vivo experiments using T650 cylinder microelectrodes show that voltammetrically measured uptake kinetics in the caudate are faster using 2,000 V/s and 240 Hz measurements, as compared to 300 V/s and 10 Hz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of voltammetry and microelectrode surface states
Kawagoe, K. T., Zimmerman, J. B., & Wightman, R. M. (1993) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(93)90094-8 · Cited by 394
Self-citationDissociation of dopamine release in the nucleus accumbens from intracranial self-stimulation
Garris, P. A., Kilpatrick, M., Bunin, M. A., Michael, D., Walker, Q. D., & Wightman, R. M. (1999) · Nature · doi:10.1038/18019 · Cited by 327
Self-citationControl of dopamine extracellular concentration in rat striatum by impulse flow and uptake
Wightman, R. M., & Zimmerman, J. B. (1990) · Brain Research Reviews · doi:10.1016/0165-0173(90)90015-g · Cited by 327
Self-citationKawagoe, K. T., Garris, P. A., Wiedemann, D. J., & Wightman, R. M. (1992) · Neuroscience · doi:10.1016/0306-4522(92)90470-m · Cited by 258
Self-citationDuVall, S. H., & McCreery, R. L. (1999) · Analytical Chemistry · doi:10.1021/ac990399d · Cited by 256
Facile Preparation of Active Glassy Carbon Electrodes with Activated Carbon and Organic Solvents
Ranganathan, S., Kuo, T.-C., & McCreery, R. L. (1999) · Analytical Chemistry · doi:10.1021/ac981386n · Cited by 187
The in vitro brain slice as a useful neurophysiological preparation for intracellular recording
Dingledine, R., Dodd, J., & Kelly, J. S. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90002-3 · Cited by 167
In vivo electrochemical measurements in the CNS
Adams, R. (1990) · Progress in Neurobiology · doi:10.1016/0301-0082(90)90014-8 · Cited by 149
Real-Time Amperometric Measurements of Zeptomole Quantities of Dopamine Released from Neurons
Hochstetler, S. E., Puopolo, M., Gustincich, S., Raviola, E., & Wightman, R. M. (1999) · Analytical Chemistry · doi:10.1021/ac991119x · Cited by 135
Self-citationRunnels, P. L., Joseph, J. D., Logman, M. J., & Wightman, R. M. (1999) · Analytical Chemistry · doi:10.1021/ac981279t · Cited by 122
Self-citation
Cited by
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Detecting Subsecond Dopamine Release with Fast-Scan Cyclic Voltammetry in Vivo
Robinson, D. L., Venton, B. J., Heien, M. L. A. V., & Wightman, R. M. (2003) · Clinical Chemistry · doi:10.1373/49.10.1763 · Cited by 606
Self-citationReal-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats
Heien, M. L. A. V., Khan, A. S., Ariansen, J. L., Cheer, J. F., Phillips, P. E. M., Wassum, K. M., & Wightman, R. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504657102 · Cited by 482
Self-citationSerotonin engages an anxiety and fear-promoting circuit in the extended amygdala
Marcinkiewcz, C. A., Mazzone, C. M., D’Agostino, G., Halladay, L. R., Hardaway, J. A., DiBerto, J. F., Navarro, M., Burnham, N., Cristiano, C., Dorrier, C. E., et al. (2016) · Nature · doi:10.1038/nature19318 · Cited by 456
Heien, M. L. A. V., Phillips, P. E. M., Stuber, G. D., Seipel, A. T., & Wightman, R. M. (2003) · The Analyst · doi:10.1039/b307024g · Cited by 385
Self-citation
Metadata
- Authors
- Bath, B. D., Michael, D. J., Trafton, B. J., Joseph, J. D., Runnels, P. L., & Wightman, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-11-17
- Volume
- 72
- Issue
- 24
- Pages
- 5994-6002
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965324392
- Cited by
- 363
- References
- 18
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes. https://app.cochat.ai/papers/10.1021/ac000849y
- The paper
- Bath, B. D., Michael, D. J., Trafton, B. J., Joseph, J. D., Runnels, P. L., & Wightman, R. M. (2000). Subsecond Adsorption and Desorption of Dopamine at Carbon-Fiber Microelectrodes. Analytical Chemistry. https://doi.org/10.1021/ac000849y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.