The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Voltammetric DNA Biosensor for Cystic Fibrosis Based on a Modified Carbon Paste Electrode
Abstract
Carbon paste electrodes modified by the inclusion of either octadecylamine or stearic acid were used as solid phases to which DNA was covalently bound. Immobilized DNA was detected by voltammetry of solutions containing submillimolar quantities of Co(bpy)3(ClO4)3, Co(phen)3(ClO4)3, and Os(bpy)3-Cl2 (bpy = 2,2'-bipyridine; phen = 1,10-phenanthroline), all of which associate reversibly with immobilized DNA and yield increased peak currents at DNA-modified electrodes. Immobilization onto octadecylamine-modified electrodes was performed using a water-soluble carbodiimide, and at high DNA concentrations in the reaction mixture, it resulted in visible polymerization of DNA on the surface. Optimization of the deoxyguanosine- (dG-) selective immobilization reaction for stearic acid-modified electrodes, using water-soluble carbodiimide and N-hydroxysulfosuccinimide reagents to activate carboxylate groups on the surface, yielded conditions of 4.5% (w/w) stearic acid and 10 micrograms/mL DNA. Polythymidylic acid of 4000-base average length (poly(dT)4000) was immobilized at stearic acid-modified electrodes following enzymatic elongation with dG residues at the 3'-end. These DNA-modified electrodes were used to study hybridization with analyte poly(dA)4000 by in situ voltammetry of 60 microM Co(bpy)3(ClO4)3 at low ionic strength (20 mM NaCl), and by voltammetry of the same complex, following exposure of the electrode to poly(dA)4000 in a separate hybridization step conducted at high ionic strength (0.5 M NaCl). Results indicate slow (> or = 1 h) hybridization at low ionic strength and fast (< or = 10 min) hybridization at high ionic strength.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MACDONALD, M. (1993) · Cell · doi:10.1016/0092-8674(93)90585-e · Cited by 8,366
Identification of the Cystic Fibrosis Gene: Cloning and Characterization of Complementary DNA
Riordan, J. R., Rommens, J. M., Kerem, B.-S., Alon, N., Rozmahel, R., Grzelczak, Z., Zielenski, J., Lok, S., Plavsic, N., Chou, J.-L., et al. (1989) · Science · doi:10.1126/science.2475911 · Cited by 7,418
Cited by
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Electrochemical nucleic acid biosensors
Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01399-x · Cited by 614
A gold nanoparticle-based chronocoulometric DNA sensor for amplified detection of DNA
Zhang, J., Song, S., Wang, L., Pan, D., & Fan, C. (2007) · Nature Protocols · doi:10.1038/nprot.2007.419 · Cited by 473
Carbon nanotube-enhanced electrochemical DNA biosensor for DNA hybridization detection
Cai, H., Cao, X., Jiang, Y., He, P., & Fang, Y. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1652-9 · Cited by 431
TELES, F., & FONSECA, L. (2008) · Talanta · doi:10.1016/j.talanta.2008.07.024 · Cited by 405
Metadata
- Authors
- Millan, K. M., Saraullo, A., & Mikkelsen, S. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-09-15
- Volume
- 66
- Issue
- 18
- Pages
- 2943-2948
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1992409348
- Cited by
- 390
- References
- 2
- FWCI
- 17.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.