The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Dynamic Coating Using Polyelectrolyte Multilayers for Chemical Control of Electroosmotic Flow in Capillary Electrophoresis Microchips
Abstract
Poly(dimethylsiloxane) (PDMS) capillary electrophoresis (CE) microchips were modified by a dynamic coating method that provided stable electroosmotic flow (EOF) with respect to pH. The separation channel was coated with a polymer bilayer consisting of a cationic layer of Polybrene (PB) and an anionic layer of dextran sulfate (DS). According to the difference in charge, PB- and PB/ DS-coated channels supported EOF in different directions; however, both methods of channel coating exhibited a pH-independent EOF in the pH range of 5-10 due to chemical control of the effective zeta-potential. The endurance of the PB-coated layer was determined to be 50 runs at pH 3.0, while PB/DS-coated chips had a stable EOF for more than 100 runs. The effect of substrate composition and chip-sealing methodology was also evaluated. All tested chips showed the same EOF on the PB/DS-coated channels, as compared to uncoated chips, which varied significantly. No significant variation for separation and electrochemical detection of dopamine and hydroquinone between coated and uncoated channels was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
Organic-Inorganic Hybrid Materials as Semiconducting Channels in Thin-Film Field-Effect Transistors
Kagan, C. R., Mitzi, D. B., & Dimitrakopoulos, C. D. (1999) · Science · doi:10.1126/science.286.5441.945 · Cited by 2,110
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Microchip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315
Locascio, L. E., Perso, C. E., & Lee, C. S. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00774-8 · Cited by 192
Comparison of methods to assess surface acidic groups on activated carbons
Bandosz, T. J., Jagiełło, J., & Schwarz, J. A. (1992) · Analytical Chemistry · doi:10.1021/ac00032a012 · Cited by 116
Cited by
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems
Erickson, D., Sinton, D., & Li, D. (2003) · Lab on a Chip · doi:10.1039/b306158b · Cited by 299
Metadata
- Authors
- Liu, Y., Fanguy, J. C., Bledsoe, J. M., & Henry, C. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-11-11
- Volume
- 72
- Issue
- 24
- Pages
- 5939-5944
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2029618098
- Cited by
- 293
- References
- 9
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.