Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 315

The DOI matches its Crossref record.

Microchip Electrophoretic Immunoassay for Serum Cortisol

Koutny, Lance B., Schmalzing, Dieter, Taylor, Todd A., Fuchs, Martin·1996·Analytical Chemistry

Abstract

An immunoassay performed using a microchip electrophoretic system is described. Separation and quantitation of free and bound labeled antigen in a competitive assay are carried out in channels micromachined into fused silica substrates. Such microchips are attractive because of their small size, ruggedness, and amenability to automated handling. The assay achieves the determination of cortisol in blood serum over the range of clinical interest (1-60 micrograms/dL) without the need for extraction or other sample preparation steps. The separation is performed in less than 30 s. Very high throughput is possible by operating the assay in multiple channels in parallel. These characteristics make microchip electrophoretic systems a promising technology for the rapid analysis of clinical samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9508311

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 315

Metadata

Authors
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M.
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
1
Pages
18-22
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1964139393
Cited by
315
References
0
FWCI
31.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microchip Electrophoretic Immunoassay for Serum Cortisol. https://app.cochat.ai/papers/10.1021/ac9508311
The paper
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996). Microchip Electrophoretic Immunoassay for Serum Cortisol. Analytical Chemistry. https://doi.org/10.1021/ac9508311

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.