The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Liquid Chromatography/Mass Spectrometry of Phospholipids using Electrospray Ionization
Abstract
An improved technique for phospholipid molecular species analysis was developed using high-performance liquid chromatography/mass spectrometry with the electrospray interface. Using the 0.5% ammonium hydroxide in a water-methanol-hexane mixture and a C-18 column, complex mixtures of phospholipid molecular species were separated and detected mainly as protonated or natriated molecular species. The response was linear over 2 orders of magnitude, allowing quantification of each molecular species. In comparison to the existing LC/MS techniques, marked improvement in sensitivity was observed. The present quantification limit is approximately 0.5 pmol before split (5 fmol after 1/100 split). The relative responses were more dependent on the head group identity rather than fatty acyl composition within a phospholipid class. In general, phosphatidylcholine (PC) species are most sensitively detected followed by phosphatidylethanolamine (PE) species. The sensitivity of phosphatidylserine (PS) in the positive ion mode is approximately 20 times less in comparison to PC under our condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Schneiter, R., Brügger, B., Sandhoff, R., Zellnig, G., Leber, A., Lampl, M., Athenstaedt, K., Hrastnik, C., Eder, S., Daum, G., et al. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.146.4.741 · Cited by 493
Koivusalo, M., Haimi, P., Heikinheimo, L., Kostiainen, R., & Somerharju, P. (2001) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)31176-7 · Cited by 417
Han, X., & Gross, R. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00568-4 · Cited by 289
Han, X., Yang, K., & Gross, R. W. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3595 · Cited by 190
Metadata
- Authors
- Kim, H.-Y., Wang, T.-C. L., & Ma, Y.-C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-11-15
- Volume
- 66
- Issue
- 22
- Pages
- 3977-3982
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2094561952
- Cited by
- 259
- References
- 2
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid Chromatography/Mass Spectrometry of Phospholipids using Electrospray Ionization. https://app.cochat.ai/papers/10.1021/ac00094a020
- The paper
- Kim, H.-Y., Wang, T.-C. L., & Ma, Y.-C. (1994). Liquid Chromatography/Mass Spectrometry of Phospholipids using Electrospray Ionization. Analytical Chemistry. https://doi.org/10.1021/ac00094a020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.