The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Quantitative determination of phospholipid compositions by ESI-MS: effects of acyl chain length, unsaturation, and lipid concentration on instrument response
Open accessAbstract
Electrospray ionization-mass spectrometry (ESI-MS) is a very promising tool for the analysis of phospholipid compositions, but is hampered by the fact that not all molecular species are detected with equal efficiency. We studied this and other issues that need to be taken into account to obtain truly quantitative compositional data. The key findings were as follows: First, the instrument response for both saturated and unsaturated phospholipid species decreased with increasing acyl chain length. This effect became increasingly prominent with increasing overall lipid concentration. Second, the degree of acyl chain unsaturation also had a significant effect on instrument response. At the highest concentration studied (10 pmol/microl), polyunsaturated species gave 40% higher intensity than the fully saturated ones. The effect of unsaturation diminished and nearly disappeared with progressive dilution. Third, the instrument response for the different head group classes varied markedly depending on the infusion solvent used. Notably, inclusion of ammonia in the infusion solvent eliminated sodium adduct formation in the positive ion mode, thus greatly simplifying the interpretation of the spectra. The fact that instrument response is dependent on many structural features, overall lipid concentration, solvent composition, and instrument settings makes it necessary to include several internal standards for each phospholipid class to obtain accurate data. Preferably, both unsaturated and saturated standards should be used. Finally, we quantified the major phospholipid classes of BHK cells using ESI-MS. The data agreed closely with those obtained with thin-layer chromatography and phosphorus analysis. This study indicates that quantitative compositional data can be obtained with ESI-MS, provided that proper attention is paid to experimental details, particularly the choice of internal standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SIMPLE METHOD FOR THE ISOLATION AND PURIFICATION OF TOTAL LIPIDES FROM ANIMAL TISSUES
Folch, J., Lees, M., & Stanley, G. H. S. (1957) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)64849-5 · Cited by 65,189
Rapid separation of lipid classes in high yield and purity using bonded phase columns.
Kaluzny, M. A., Duncan, L. A., Merritt, M. V., & Epps, D. E. (1985) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)34412-6 · Cited by 964
Brügger, B., Erben, G., Sandhoff, R., Wieland, F. T., & Lehmann, W. D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.6.2339 · Cited by 881
Late endosomal membranes rich in lysobisphosphatidic acid regulate cholesterol transport
Kobayashi, T., Beuchat, M.-H., Lindsay, M., Frias, S., Palmiter, R. D., Sakuraba, H., Parton, R. G., & Gruenberg, J. (1999) · Nature Cell Biology · doi:10.1038/10084 · Cited by 620
Patton, G. M., Fasulo, J. M., & Robins, S. J. (1982) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38188-8 · Cited by 534
Martin, T. F. J. (1998) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.14.1.231 · Cited by 522
Schneiter, R., Brügger, B., Sandhoff, R., Zellnig, G., Leber, A., Lampl, M., Athenstaedt, K., Hrastnik, C., Eder, S., Daum, G., et al. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.146.4.741 · Cited by 493
Lipid translocation across the plasma membrane of mammalian cells
Bevers, E. M., Comfurius, P., Dekkers, D. W. C., & Zwaal, R. F. A. (1999) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/s1388-1981(99)00110-9 · Cited by 445
Han, X., & Gross, R. W. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.22.10635 · Cited by 435
DeLong, C. J., Shen, Y.-J., Thomas, M. J., & Cui, Z. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.42.29683 · Cited by 416
Cited by
Lipids in exosomes: current knowledge and the way forward
Skotland, T., Sandvig, K., & Llorente, A. (2017) · Progress in Lipid Research · doi:10.1016/j.plipres.2017.03.001 · Cited by 1,030
Han, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
Axonal loss and neuroinflammation caused by peroxisome-deficient oligodendrocytes
Kassmann, C. M., Lappe-Siefke, C., Baes, M., Brügger, B., Mildner, A., Werner, H. B., Natt, O., Michaelis, T., Prinz, M., Frahm, J., et al. (2007) · Nature Genetics · doi:10.1038/ng2070 · Cited by 357
Analytical Challenges and Recent Advances in Mass Spectrometry Based Lipidomics
Rustam, Y. H., & Reid, G. E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04836 · Cited by 282
Comprehensive quantification of ceramide species in human stratum corneum
Masukawa, Y., Narita, H., Sato, H., Naoe, A., Kondo, N., Sugai, Y., Oba, T., Homma, R., Ishikawa, J., Takagi, Y., et al. (2009) · Journal of Lipid Research · doi:10.1194/jlr.d800055-jlr200 · Cited by 228
Metadata
- Authors
- Koivusalo, M., Haimi, P., Heikinheimo, L., Kostiainen, R., & Somerharju, P.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 42
- Issue
- 4
- Pages
- 663-672
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W2106062306
- Cited by
- 417
- References
- 28
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative determination of phospholipid compositions by ESI-MS: effects of acyl chain length, unsaturation, and lipid concentration on instrument response. https://app.cochat.ai/papers/10.1016/s0022-2275(20)31176-7
- The paper
- Koivusalo, M., Haimi, P., Heikinheimo, L., Kostiainen, R., & Somerharju, P. (2001). Quantitative determination of phospholipid compositions by ESI-MS: effects of acyl chain length, unsaturation, and lipid concentration on instrument response. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)31176-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.