The DOI matches its Crossref record.
Mass Spectrometric Immunoassay
Abstract
A new, general method of immunoassay is demonstrated. The approach is based on the microscale immunoaffinity capture of target antigens followed by mass-specific identification and quantitation using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Immunoaffinity capture of antigens effectively overcomes signal suppression effects typically encountered during traditional matrix-assisted laser desorption/ionization analysis of complex biological mixtures while simultaneously concentrating the analyte into a small volume. Mass spectrometric detection of antigens is unambiguous, as antigen signals are observed at characteristic mass-to-charge values in the mass spectrum, offering a high level of immunity to artifacts due to nonbiospecific retention of mixture components. However, the most important aspect of such mass-specific detection is the ability to use a single assay to screen biological systems for the presence of multiple, mass-resolved antigens. Analyte quantitation is possible by using a single antibody to capture both the antigen and an antigen variant which has been chemically modified to have a different mass. With proper calibration, the relative signal intensities of the two species in the mass spectrum can be used to determine the antigen concentration. Sample incubation and processing methods were such that a typical analysis could be performed in less than 1 h while subnanomolar sensitivities were maintained. The technique has been used for the rapid, selective, and quantitative screening of human blood for the presence of myotoxin a, and Mojave toxin form the venoms of the prairie rattlesnakes, Crotalus viridis viridis, and and the Mojave rattlesnake, Crotalus scutulatus scutulatus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 834
Recent advancements in surface-enhanced laser desorption/ionization-time of flight-mass spectrometry
Merchant, M., & Weinberger, S. R. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.0.co;2-0 · Cited by 693
Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003) · Analytical Chemistry · doi:10.1021/ac026468x · Cited by 653
Current developments in SELDI affinity technology
Tang, N., Tornatore, P., & Weinberger, S. R. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10066 · Cited by 425
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Metadata
- Authors
- Nelson, R. W., Krone, J. R., Bieber, A. L., & Williams, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-04-01
- Volume
- 67
- Issue
- 7
- Pages
- 1153-1158
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4243937066
- Cited by
- 254
- References
- 0
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass Spectrometric Immunoassay. https://app.cochat.ai/papers/10.1021/ac00103a003
- The paper
- Nelson, R. W., Krone, J. R., Bieber, A. L., & Williams, P. (1995). Mass Spectrometric Immunoassay. Analytical Chemistry. https://doi.org/10.1021/ac00103a003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.