Simultaneous Measurement of Dopamine and Ascorbate at Their Physiological Levels Using Voltammetric Microprobe Based on Overoxidized Poly(1,2-phenylenediamine)-Coated Carbon Fiber

Mo, Jian-Wei, Ogorevc, Božidar·2001·Analytical Chemistry

Abstract

Overoxidized poly-(1,2-phenylenediamine) (OPPD)-coated carbon fiber microelectrodes (CFMEs) exhibit, in combination with square-wave voltammetry (SWV) detection mode, the attractive ability to simultaneously measure low nM dopamine (DA) and mM ascorbate (AA) in a pH 7.4 medium. The PPD polymer film is electrodeposited onto a carbon fiber at a constant potential of 0.8 V versus Ag/AgCl using a solution containing sodium dodecylsulfate as the dopant. After overoxidation using cyclic voltammetry (CV) in the potential range from 0 to 2.2 V at a scan rate of 10 V/s, the resulting OPPD-CFME displays a high SWV current response to cationic DA at approximately 0.2 V and has a favorably low response to anionic AA at approximately 0.0 V vs Ag/AgCl. The preparation of the new OPPD-sensing film has been carefully studied and optimized. The OPPD properties and behavior were characterized using CV and SWV under various conditions and are discussed with respect to DA and AA detection. The linear calibration range for DA in the presence of 0.3 mM AA is 50 nM to 10 microM, with a correlation coefficient of 0.998 and a detection limit of 10 nM using 45-s accumulation. The detection limit for DA in the absence of AA was estimated to be 2 nM (S/N = 3). The linear range for AA in the presence of 100 nM DA is 0.2-2 mM, with a correlation coefficient of 0.999 and a detection limit of 80 microM. The reproducibilities of SWV measurements at OPPD-CFCMEs are 1.6% and 2.5% for 100 nM DA and 0.3 mM AA, respectively. Potential interfering agents, such as 3,4-dihydroxyphenylacetic acid, uric acid, oxalate, human serum proteins, and glucose, at their physiologically relevant or higher concentrations did not have any effect. These favorable features offer great promise for in vitro and in vivo application of the proposed OPPD-coated microprobe.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0010882

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Mo, J.-W., & Ogorevc, B.
Venue
Analytical Chemistry
Published
2001-02-10
Volume
73
Issue
6
Pages
1196-1202
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2072544666
Cited by
353
References
17
FWCI
11.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.