The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electric Manipulation of Bioparticles and Macromolecules on Microfabricated Electrodes
Abstract
Bioparticle separation, bioparticle enrichment, and electric field-mediated immune detection were carried out on microfabricated semiconductor chips utilizing ac and dc electric fields. Microscale separation on a chip surface having an active area of approximately 16 mm2 was demonstrated for a mixture of Bacillus globigii spores and Escherichia coli bacteria. Dielectrophoretic enrichment was performed by collecting target bioparticles from a flow stream in flow cells of 47.5 microL, achieving a 20-fold increase in the concentration of E. coli bacteria from a diluted sample, a 28-fold enrichment for peripheral blood mononuclear cells from red blood cells, and a 30-fold increase in white blood cells from diluted whole blood. The ability to manipulate and collect bioparticles and macromolecules at microfabricated electrodes with ac and dc fields was further illustrated in electric field-mediated immunoassays for analyzing the biological identities of E. coli bacteria and B. globigii spores. According to these results, the electric methods for manipulating bioparticles present themselves as viable techniques for novel biomedical applications in sample preparations and biochemical assays on microelectrode arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Cited by
DNA Microarray Technology: Devices, Systems, and Applications
Heller, M. J. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153438 · Cited by 1,068
Self-citationMicrofluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Metadata
- Authors
- Huang, Y., Ewalt, K. L., Tirado, M., Haigis, R., Forster, A., Ackley, D., Heller, M. J., O'Connel, J. P., & Krihak, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-15
- Volume
- 73
- Issue
- 7
- Pages
- 1549-1559
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980940308
- Cited by
- 161
- References
- 1
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.