Thrombogenic Properties of Untreated and Poly(ethylene oxide)-Modified Polymeric Matrixes Useful for Preparing Intraarterial Ion-Selective Electrodes
The DOI matches its Crossref record.
Abstract
In vitro platelet adhesion studies are used to compare the thrombogenic properties of various polymer matrices useful for preparing implantable ion-selective membrane electrodes. Conventional plasticized poly(vinyl chloride) and alternate polyurethane materials (Tecoflex, Pellethane) doped with proton- (tridodecylamine) and potassium-selective (valinomycin) ionophores are shown to be potentially thrombogenic. Incorporation of high molecular weight block copolymers of poly(ethylene oxide) and poly(propylene oxide) (e.g., Pluronic F108 and Tetronic 1508) within ion-selective membranes reduces platelet adhesion. A more marked decrease in platelet adhesion is, however, observed when the Tecoflex-based membranes are coated with a thin photo-cross-linked layer of poly(ethylene oxide). Such surface-modified membranes are shown to retain potentiometric ion response properties (i.e., selectivity, response times, response slopes, etc.) essentially equivalent to untreated membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
Bakker, E., Bühlmann, P., & Pretsch, E. (1997) · Chemical Reviews · doi:10.1021/cr940394a · Cited by 2,369
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Polymers in sensor applications
Adhikari, B., & Majumdar, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.03.002 · Cited by 1,181
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Metadata
- Authors
- Espadas-Torre, C., & Meyerhoff, M. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-09-15
- Volume
- 67
- Issue
- 18
- Pages
- 3108-3114
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048124130
- Cited by
- 117
- References
- 0
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thrombogenic Properties of Untreated and Poly(ethylene oxide)-Modified Polymeric Matrixes Useful for Preparing Intraarterial Ion-Selective Electrodes. https://app.cochat.ai/papers/10.1021/ac00114a003
- The paper
- Espadas-Torre, C., & Meyerhoff, M. E. (1995). Thrombogenic Properties of Untreated and Poly(ethylene oxide)-Modified Polymeric Matrixes Useful for Preparing Intraarterial Ion-Selective Electrodes. Analytical Chemistry. https://doi.org/10.1021/ac00114a003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.