The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determination of Clenbuterol in Bovine Liver by Combining Matrix Solid-Phase Dispersion and Molecularly Imprinted Solid-Phase Extraction Followed by Liquid Chromatography/Electrospray Ion Trap Multiple-Stage Mass Spectrometry
Abstract
Matrix solid-phase dispersion (MSPD) is a new sample pretreatment for solid samples. This technique greatly simplifies sample pretreatment but, nonetheless, the extracts often still require an extra cleanup step that is both laborious and time-consuming. The potential of combining MSPD with molecularly imprinted solid-phase extraction (MISPE) was investigated in this study. Liver samples were ground in a mortar with C18 sorbent and the homogenized mixture packed into an SPE cartridge and placed on top of a MISPE cartridge. Subsequently, clenbuterol was eluted from the MSPD cartridge onto the MISPE cartridge using acetonitrile containing 1% acetic acid. The ability of the molecularly imprinted polymer to selectively adsorb analyte in acetonitrile was exploited for re-extracting clenbuterol directly from this acetonitrile extract via the double cartridge tandem system. The analyte was eluted from the MISPE cartridge using acidified methanol. A clear eluate was obtained, which was subsequently evaporated, redissolved, and analyzed by HPLC electrochemical detection (ECD) or ion trap mass spectrometry (LC/IT-MS). The MISPE cartridge used in this study was imprinted using bromoclenbuterol, a structural analogue of clenbuterol, as the template. These MISPE cartridges showed excellent stability. The complete extraction procedure was rapid, and recoveries exceeded 90% for the target analyte. The method detection limit for the LC/IT-MS procedure was < 0.1 microg/kg. This method, therefore, satisfies the stringent requirements of European Union regulation EEC 2377/90.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of a β-Agonist to Alter Fat and Muscle Deposition in Steers1
Ricks, C. A., Dalrymple, R. H., Baker, P. K., & Ingle, D. L. (1984) · Journal of Animal Science · doi:10.2527/jas1984.5951247x · Cited by 294
Cited by
Alexander, C., Andersson, H. S., Andersson, L. I., Ansell, R. J., Kirsch, N., Nicholls, I. A., O'Mahony, J., & Whitcombe, M. J. (2006) · Journal of Molecular Recognition · doi:10.1002/jmr.760 · Cited by 1,248
Molecularly imprinted polymers for sample preparation: A review
Turiel, E., & Martín-Esteban, A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.04.019 · Cited by 508
Before the injection—Modern methods of sample preparation for separation techniques
Smith, R. M. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00511-9 · Cited by 503
He, C., Long, Y., Pan, J., Li, K., & Liu, F. (2007) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2006.07.005 · Cited by 371
CARO, E., MARCE, R., BORRULL, F., CORMACK, P., & SHERRINGTON, D. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.05.008 · Cited by 338
Self-citationPorous graphitic carbon: A versatile stationary phase for liquid chromatography
West, C., Elfakir, C., & Lafosse, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.052 · Cited by 270
New trends in sample preparation for clinical and pharmaceutical analysis
Kataoka, H. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00402-3 · Cited by 261
Solid phase extraction of food contaminants using molecular imprinted polymers
Baggiani, C., Anfossi, L., & Giovannoli, C. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.01.056 · Cited by 253
Metadata
- Authors
- Crescenzi, C., Bayoudh, S., Cormack, P. A. G., Klein, T., & Ensing, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-11
- Volume
- 73
- Issue
- 10
- Pages
- 2171-2177
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2091819486
- Cited by
- 160
- References
- 1
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.