Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of Clenbuterol in Bovine Liver by Combining Matrix Solid-Phase Dispersion and Molecularly Imprinted Solid-Phase Extraction Followed by Liquid Chromatography/Electrospray Ion Trap Multiple-Stage Mass Spectrometry

Crescenzi, C., Bayoudh, S., Cormack, P. A. G., Klein, T., Ensing, K.·2001·Analytical Chemistry

Abstract

Matrix solid-phase dispersion (MSPD) is a new sample pretreatment for solid samples. This technique greatly simplifies sample pretreatment but, nonetheless, the extracts often still require an extra cleanup step that is both laborious and time-consuming. The potential of combining MSPD with molecularly imprinted solid-phase extraction (MISPE) was investigated in this study. Liver samples were ground in a mortar with C18 sorbent and the homogenized mixture packed into an SPE cartridge and placed on top of a MISPE cartridge. Subsequently, clenbuterol was eluted from the MSPD cartridge onto the MISPE cartridge using acetonitrile containing 1% acetic acid. The ability of the molecularly imprinted polymer to selectively adsorb analyte in acetonitrile was exploited for re-extracting clenbuterol directly from this acetonitrile extract via the double cartridge tandem system. The analyte was eluted from the MISPE cartridge using acidified methanol. A clear eluate was obtained, which was subsequently evaporated, redissolved, and analyzed by HPLC electrochemical detection (ECD) or ion trap mass spectrometry (LC/IT-MS). The MISPE cartridge used in this study was imprinted using bromoclenbuterol, a structural analogue of clenbuterol, as the template. These MISPE cartridges showed excellent stability. The complete extraction procedure was rapid, and recoveries exceeded 90% for the target analyte. The method detection limit for the LC/IT-MS procedure was < 0.1 microg/kg. This method, therefore, satisfies the stringent requirements of European Union regulation EEC 2377/90.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0014360

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Crescenzi, C., Bayoudh, S., Cormack, P. A. G., Klein, T., & Ensing, K.
Venue
Analytical Chemistry
Published
2001-04-11
Volume
73
Issue
10
Pages
2171-2177
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2091819486
Cited by
160
References
1
FWCI
9.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.