The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Automated instrumentation for comprehensive two-dimensional high-performance liquid chromatography of proteins
Abstract
A comprehensive two-dimensional (2-D) liquid chromatographic separation system is presented. The system uses a microbore cation exchange column, operated under gradient conditions, as the first dimension separation. Effluent from this first column alternately fills one of two loops on a computer-controlled eight-port valve. A second pump then forces loop material onto a second column, a size exclusion column. UV detection is used, and the system is applied to the separation of protein standards and serum proteins. The 2-D system has a higher resolving power and peak capacity than either of the two columns used alone. The entire first column effluent is analyzed on the second column in virtually the same time it takes to complete the first column separation, without the use of stopped flow methods. The entire system is automated and operated under computer control. Three-dimensional (3-D) data representation provides a means of viewing peak profiles in either separation dimension and contour mapping of the 3-D data provides a more reliable means of peak identification from run to run than that provided by single-column elution times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Analytical techniques for cell fractions
Pearson, T., & Anderson, L. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90203-1 · Cited by 622
Two-dimensional separations: concept and promise
Giddings, J. C. (1984) · Analytical Chemistry · doi:10.1021/ac00276a003 · Cited by 537
Concepts and comparisons in multidimensional separation
Giddings, J. C. (1987) · Journal of High Resolution Chromatography · doi:10.1002/jhrc.1240100517 · Cited by 466
Davis, J. M., & Giddings, J. C. (1985) · Analytical Chemistry · doi:10.1021/ac00289a002 · Cited by 139
Davis, G. C., & Kissinger, P. T. (1979) · Analytical Chemistry · doi:10.1021/ac50048a016 · Cited by 46
Cited by
Fast, comprehensive two-dimensional liquid chromatography
Stoll, D. R., Li, X., Wang, X., Carr, P. W., Porter, S. E. G., & Rutan, S. C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.054 · Cited by 396
On-line preconcentration methods for capillary electrophoresis
Osbourn, D. M., Weiss, D. J., & Lunte, C. E. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000801)21:14<2768::aid-elps2768>3.0.co;2-p · Cited by 327
Wagner, K., Miliotis, T., Marko-Varga, G., Bischoff, R., & Unger, K. K. (2002) · Analytical Chemistry · doi:10.1021/ac010627f · Cited by 258
A New Dimension in Separation Science: Comprehensive Two‐Dimensional Gas Chromatography
Meinert, C., & Meierhenrich, U. J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200842 · Cited by 106
Baghdady, Y. Z., & Schug, K. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01665 · Cited by 36
Metadata
- Authors
- Bushey, M. M., & Jorgenson, J. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-01-15
- Volume
- 62
- Issue
- 2
- Pages
- 161-167
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2016022626
- Cited by
- 350
- References
- 6
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.