The DOI matches its Crossref record.
Noninvasive method for monitoring ethanol in fermentation processes using fiber-optic near-infrared spectroscopy
Abstract
Short-wavelength near-infrared (SW-near-IR) spectroscopy (700-1100 nm) is used for the determination of ethanol during the time course of a fermentation. Measurements are performed noninvasively by means of a photodiode array spectrometer equipped with a fiber-optic probe placed on the outside of the glass-wall fermentation vessel. Pure ethanol/water and ethanol/yeast/water mixtures are studied to establish the spectral features that characterize ethanol and to show that determination of ethanol is independent of the yeast concentration. Analysis of the second-derivative data is accomplished with multilinear regression (MLR). The standard error of prediction (SEP) of ethanol in ethanol/water solutions is approximately 0.2% over a range of 0-15%; the SEP of ethanol in ethanol/yeast/water solutions is 0.27% (w/w). Results from the mixture experiments are then applied to actual yeast fermentations of glucose to ethanol. By use of a gas chromatographic method for validation, a good correlation is found between the intensity of backscattered light at 905 nm and the actual ethanol. Additional experiments show that a calibration model created for one fermentation can be used to predict ethanol production during the time course of others with a prediction error of 0.4%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
Interpretive Spectroscopy for Near Infrared
Workman, J. J. (1996) · Applied Spectroscopy Reviews · doi:10.1080/05704929608000571 · Cited by 254
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Optical sensor systems for bioprocess monitoring
Marose, S. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(98)01247-5 · Cited by 102
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84
Metadata
- Authors
- Cavinato, A. G., Mayes, D. M., Ge, Z., & Callis, J. B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-09-01
- Volume
- 62
- Issue
- 18
- Pages
- 1977-1982
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1986026409
- Cited by
- 158
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive method for monitoring ethanol in fermentation processes using fiber-optic near-infrared spectroscopy. https://app.cochat.ai/papers/10.1021/ac00217a015
- The paper
- Cavinato, A. G., Mayes, D. M., Ge, Z., & Callis, J. B. (1990). Noninvasive method for monitoring ethanol in fermentation processes using fiber-optic near-infrared spectroscopy. Analytical Chemistry. https://doi.org/10.1021/ac00217a015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.