The DOI matches its Crossref record.
A Real-Time Ratiometric Method for the Determination of Molecular Oxygen Inside Living Cells Using Sol−Gel-Based Spherical Optical Nanosensors with Applications to Rat C6 Glioma
Abstract
The first sol-gel-based, ratiometric, optical nanosensors, or sol-gel probes encapsulated by biologically localized embedding (PEBBLEs), are made and demonstrated here to enable reliable, real-time measurements of subcellular molecular oxygen. Sensors were made using a modified Stöber method, with poly(ethylene glycol) as a steric stabilizer. The radii of these spherical PEBBLE sensors range from about 50 to 300 nm. These sensors incorporate an oxygen-sensitive fluorescent indicator, Ru(II)-tris(4,7-diphenyl-1,10-phenanthroline) chloride ([Ru(dpp)3]2+), and an oxygen-insensitive fluorescent dye, Oregon Green 488-dextran, as a reference for the purpose of ratiometric intensity measurements. The PEBBLE sensors have excellent reversibility, dynamic range, and stability to leaching and photobleaching. The small size and inert matrix of these sensors allow them to be inserted into living cells with minimal physical and chemical perturbations to their biological functions. Applications of sol-gel PEBBLEs inserted in rat C6 glioma cells for real-time intracellular oxygen analysis are demonstrated. Compared to using free dyes for intracellular measurements, the PEBBLE matrix protects the fluorescent dyes from interference by proteins in cells, enabling reliable in vivo chemical analysis. Conversely, the matrix also significantly reduces the toxicity of the indicator and reference dyes to the cells, so that a wide variety of dyes can be used in optimal fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Burns, A., Ow, H., & Wiesner, U. (2006) · Chem. Soc. Rev. · doi:10.1039/b600562b · Cited by 849
Nanoparticles as vehicles for delivery of photodynamic therapy agents
Bechet, D., Couleaud, P., Frochot, C., Viriot, M.-L., Guillemin, F., & Barberi-Heyob, M. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.07.007 · Cited by 760
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
El-Sewify, I. M., Shenashen, M. A., Shahat, A., Selim, M. M., Khalil, M. M. H., & El-Safty, S. A. (2018) · Microchemical Journal · doi:10.1016/j.microc.2018.02.002 · Cited by 86
Wesseler, M. F., Johansen, M. N., Kızıltay, A., Mortensen, K. I., & Larsen, N. B. (2022) · Lab on a Chip · doi:10.1039/d2lc00063f · Cited by 19
Metadata
- Authors
- Xu, H., Aylott, J. W., Kopelman, R., Miller, T. J., & Philbert, M. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-08-03
- Volume
- 73
- Issue
- 17
- Pages
- 4124-4133
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2086018869
- Cited by
- 331
- References
- 0
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.