The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Direct and Simultaneous Determination of Copper, Chromium, Aluminum, and Manganese in Urine with a Multielement Graphite Furnace Atomic Absorption Spectrometer
Abstract
A simple method was developed for the direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine using a multielement GFAAS (Perkin-Elmer SIMAA6000). Pd was used as the chemical modifier along with a special purge gas (5% H2 in Ar). A simple calibration curve method can be used (with 1:1 dilution). A standard reference material (Seronorm Trace Elements Urine) was used to find the optimal temperature program and to confirm the accuracy of the technique. The analyzed values were within 90-110% of the certified values. The relative standard deviations were 1.7, 1.5, 1.6, and 1.5% for these four elements and the detection limits were 0.08 microg L(-1) for Cu, 0.05 microg L(-1) for Cr, 0.06 microg L(-1) for Al, and 0.06 microg L(-1) for Mn. The recoveries of Cu, Cr, Al, and Mn from real urine samples were 100 +/- 5%, except for Cu (80%). The found values of Cu, Cr, Al, and Mn in a real urine sample were 14.3, 0.78, 18.9, and 0.06 microg L(-1), respectively. Scanning electron micrographs were used to investigate the physical form of Pd on the surface of the platform in the graphite furnace. Use of 5% H2 in Ar as the purge gas resulted in smaller and more uniformly distributed Pd particles (Pd particle diameters 0.4-0.6 microm using 5% H2 in Ar compared to 0.4-1.2 microm using pure Ar), increasing the effect of the Pd chemical modifier and promoting the efficiency of atomization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jouhanneau, P., Raisbeck, G. M., Yiou, F., Lacour, B., Banide, H., & Drüeke, T. B. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1023 · Cited by 65
Cited by
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
Carbon Dots Based Dual-Emission Silica Nanoparticles as a Ratiometric Nanosensor for Cu2+
Liu, X., Zhang, N., Bing, T., & Shangguan, D. (2014) · Analytical Chemistry · doi:10.1021/ac404236y · Cited by 308
Metadata
- Authors
- Lin, T.-W., & Huang, S.-D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-08-01
- Volume
- 73
- Issue
- 17
- Pages
- 4319-4325
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043730665
- Cited by
- 203
- References
- 1
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct and Simultaneous Determination of Copper, Chromium, Aluminum, and Manganese in Urine with a Multielement Graphite Furnace Atomic Absorption Spectrometer. https://app.cochat.ai/papers/10.1021/ac010319h
- The paper
- Lin, T.-W., & Huang, S.-D. (2001). Direct and Simultaneous Determination of Copper, Chromium, Aluminum, and Manganese in Urine with a Multielement Graphite Furnace Atomic Absorption Spectrometer. Analytical Chemistry. https://doi.org/10.1021/ac010319h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.