The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Highly Sensitive and Selective Colorimetric and Off−On Fluorescent Chemosensor for Cu2+ in Aqueous Solution and Living Cells
Abstract
The design and synthesis of a novel rhodamine spirolactam derivative and its application in fluorescent detections of Cu(2+) in aqueous solution and living cells are reported. The signal change of the chemosensor is based on a specific metal ion induced reversible ring-opening mechanism of the rhodamine spirolactam. It exhibits a highly sensitive "turn-on" fluorescent response toward Cu(2+) in aqueous solution with an 80-fold fluorescence intensity enhancement under 10 equiv of Cu(2+) added. This indicates that the synthesized chemosensor effectively avoided the fluorescence quenching for the paramagnetic nature of Cu(2+) via its strong binding capability toward Cu(2+). With the experimental conditions optimized, the probe exhibits a dynamic response range for Cu(2+) from 8.0 x 10(-7) to 1.0 x 10(-5) M, with a detection limit of 3.0 x 10(-7) M. The response of the chemosensor for Cu(2+) is instantaneous and reversible. Most importantly, both the color and fluorescence changes of the chemosensor are remarkably specific for Cu(2+) in the presence of other heavy and transition metal ions (even those that exist in high concentration), which meet the selective requirements for biomedical and environmental monitoring application. The proposed chemosensor has been used for direct measurement of Cu(2+) content in river water samples and imaging of Cu(2+) in living cells with satisfying results, which further demonstrates its value of practical applications in environmental and biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Lichtman, J. W., & Conchello, J.-A. (2005) · Nature Methods · doi:10.1038/nmeth817 · Cited by 1,742
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Fluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179
Synthetic fluorescent sensors for studying the cell biology of metals
Domaille, D. W., Que, E. L., & Chang, C. J. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.69 · Cited by 1,081
Jung, H. S., Kwon, P. S., Lee, J. W., Kim, J. I., Hong, C. S., Kim, J. W., Yan, S., Lee, J. Y., Lee, J. H., Joo, T., et al. (2009) · Journal of the American Chemical Society · doi:10.1021/ja808611d · Cited by 1,058
Cited by
Carbon Dots Based Dual-Emission Silica Nanoparticles as a Ratiometric Nanosensor for Cu2+
Liu, X., Zhang, N., Bing, T., & Shangguan, D. (2014) · Analytical Chemistry · doi:10.1021/ac404236y · Cited by 308
Grover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Metadata
- Authors
- Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-27
- Volume
- 81
- Issue
- 16
- Pages
- 7022-7030
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2088380918
- Cited by
- 455
- References
- 57
- FWCI
- 14.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Selective Colorimetric and Off−On Fluorescent Chemosensor for Cu2+ in Aqueous Solution and Living Cells. https://app.cochat.ai/papers/10.1021/ac901127n
- The paper
- Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009). Highly Sensitive and Selective Colorimetric and Off−On Fluorescent Chemosensor for Cu2+ in Aqueous Solution and Living Cells. Analytical Chemistry. https://doi.org/10.1021/ac901127n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.