The DOI matches its Crossref record.
Selective Permeation of Hydrogen Peroxide through Polyelectrolyte Multilayer Films and Its Use for Amperometric Biosensors
Abstract
A platinum electrode was coated with polyelectrolyte multilayer (PEM) films to prepare an amperometric hydrogen peroxide sensor which can be used in the presence of possible interferences such as ascorbic acid, uric acid, and acetaminophen. The PEM films were prepared on the surface of a Pt disk electrode by an alternate deposition of polycation and polyanion from the aqueous solutions through electrostatic force of attraction. The Pt electrodes coated with a poly(allylamine)/poly(vinyl sulfate) or poly(allylamine)/poly(styrenesulfonate) film were used successfully for detecting H2O2 selectively in the presence of the possible interfering agents. It was suggested that H2O2 can diffuse into the PEM film smoothly while the ascorbic acid, uric acid, and acetaminophen cannot penetrate the film by a size exclusion mechanism. On the other hand, the electrodes coated with PEM films containing poly(ethyleneimine) or poly(diallyldimethylammonium chloride) were not useful for the selective determination of H2O2. The results were rationalized based on the different permeability of the films due to the different molecular density or packing in the PEM films. The PEM film-coated electrode was useful for constructing glucose biosensors by coupling with glucose oxidase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of Layer‐by‐Layer Assembly: From Biomimetics to Tissue Engineering
Tang, Z., Wang, Y., Podsiadlo, P., & Kotov, N. A. (2006) · Advanced Materials · doi:10.1002/adma.200600113 · Cited by 1,302
Form and Function in Multilayer Assembly: New Applications at the Nanoscale
Hammond, P. T. (2004) · Advanced Materials · doi:10.1002/adma.200400760 · Cited by 1,251
Tailor‐Made Polyelectrolyte Microcapsules: From Multilayers to Smart Containers
Peyratout, C. S., & Dähne, L. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300568 · Cited by 1,031
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Electrochemically enabled polyelectrolyte multilayer devices: from fuel cells to sensors
Lutkenhaus, J. L., & Hammond, P. T. (2007) · Soft Matter · doi:10.1039/b701203a · Cited by 264
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075007 · Cited by 182
Thermally controlled preferential molecular aggregation state in a thiacarbocyanine dye
Passier, R., Ritchie, J. P., Toro, C., Diaz, C., Masunov, A. E., Belfield, K. D., & Hernandez, F. E. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3483896 · Cited by 25
Metadata
- Authors
- Hoshi, T., Saiki, H., Kuwazawa, S., Tsuchiya, C., Chen, Q., & Anzai, J.-I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-09-28
- Volume
- 73
- Issue
- 21
- Pages
- 5310-5315
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1995042272
- Cited by
- 168
- References
- 0
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.