A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring
Open accessAbstract
We present an integrated functional contact lens, composed of a differential glucose sensor module, metal interconnects, sensor read-out circuit, antenna and telecommunication circuit, to monitor tear glucose levels wirelessly, continuously and non-invasively. The electrochemical differential sensor module is based on immobilization of activated and de-activated glucose oxidase. We characterized the sensor on a model polymer eye and determined that it showed good repeatability, molecular interference rejection and linearity in the range of 0–2 mM glucose, covering normal tear glucose concentrations (0.1–0.6 mM). We also report the temperature, ageing and protein-fouling sensitivity of the sensor. We report the design and implementation of a low-power (3 µW) sensor read-out and telecommunication circuit to deliver wireless power and transmit data for the sensor module. Using this small chip (0.36 mm 2 ), we produced an integrated contact lens with sensors and demonstrated wireless operation of the system and glucose read-out over the distance of several centimeters.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wearable tear biosensors have been used for continuous glucose monitoring since 2007 and later for lactate sensing since 2012.
“Wearable tear biosensors have been used for continuous glucose monitoring since 2007 [147,148,149], and later for lactate sensing since 2012 [150].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [149]
The Parviz team demonstrated electrochemical biosensing and investigated different biosensing strategies to achieve good sensitivity, linearity and accuracy.
“Further advances for the field came with the demonstration of electrochemical biosensing by the Parviz team114-116. This group investigated different biosensing strategies to achieve good sensitivity, linearity and accuracy.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [115]
The Parviz team resolved interference issues by introducing the 'dual sensor setup' that implements additional control (GOx-free) working and counter electrodes.
“Also, they were able to resolve interference issues by introducing the ‘dual sensor setup’ that implements additional control (GOx-free) working and counter electrodes114,115.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [115]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Katz, E. Y., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,358 · see citing works
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · see citing works
Self-citationBerman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 476 · see citing works
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372 · see citing works
Self-citationStress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., Lords, A. O., Raŝković, D., Cox, P. G., Adhami, R. R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 372 · see citing works
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300 · see citing works
Mansouri, K., & Shaarawy, T. M. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 230 · see citing works
Self-assembled single-crystal silicon circuits on plastic
Stauth, S. A., & Parviz, B. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602893103 · Cited by 215 · see citing works
Self-citationThe role of tear physiology in ocular surface temperature
Craig, J. P., Singh, I., Tomlinson, A., Morgan, P. B., & Efron, N. (2000) · Eye · doi:10.1038/eye.2000.156 · Cited by 193 · see citing works
Hoshi, T., Saiki, H., Kuwazawa, S., Tsuchiya, C., Chen, Q., & Anzai, J. (2001) · Analytical Chemistry · doi:10.1021/ac010605t · Cited by 168 · see citing works
Tear Glucose Dynamics in Diabetes Mellitus
Lane, J., Krumholz, D. M., Sack, R. A., & Morris, C. (2006) · Current Eye Research · doi:10.1080/02713680600976552 · Cited by 160 · see citing works
A single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148 · see citing works
Žoldák, G., Zubrík, A., Musatov, A., Stupák, M., & Sedlák, E. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m406883200 · Cited by 142 · see citing works
Palmisano, F., Rizzi, R., Centonze, D., & Zambonin, P. G. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00107-x · Cited by 138 · see citing works
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129 · see citing works
Self-assembled monolayers and enzyme electrodes: Progress, problems and prospects
Creager, S. E., & Olsen, K. G. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00506-h · Cited by 108 · see citing works
A fully integrated RF-powered contact lens with a single element display
Pandey, J., Liao, Y.-T., Lingley, A., Mirjalili, R., Parviz, B., & Otis, B. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081989 · Cited by 96 · see citing works
Self-citationBiomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents
Chu, M., Shirai, T., Takahashi, D., Arakawa, T., Kudo, H., Sano, K., Sawada, S.-I., Yano, K., Iwasaki, Y., Akiyoshi, K., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9530-x · Cited by 85 · see citing works
Mirejovsky, D., Patel, A. S., Rodriguez, D. D., et al. (1991) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1991.tb02837.x · Cited by 76 · see citing works
Clinical Trial of a Noninvasive Contact Lens Glucose Sensor
March, W. F., Mueller, A., & Herbrechtsmeier, P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.782 · Cited by 74 · see citing works
Xue, H., Shen, Z., & Li, C. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.018 · Cited by 66 · see citing works
Self-assembled crystalline semiconductor optoelectronics on glass and plastic
Saeedi, E., Kim, S., & Parviz, B. A. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/7/075019 · Cited by 58 · see citing works
Self-citationA wireless magnetoelastic biosensor for rapid detection of glucose concentrations in urine samples
Gao, X., Yang, W., Pang, P., Liao, S., Cai, Q., Zeng, K., & Grimes, C. A. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.05.045 · Cited by 52 · see citing works
Plant tissue-based amperometric electrode for eliminating ascorbic acid interferences
Wang, J., Naser, N., & Özsöz, M. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83572-2 · Cited by 31 · see citing works
Lin, S. P., & Brenner, H. (1982) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(82)90136-9 · Cited by 29 · see citing works
A dual microscale glucose sensor on a contact lens, tested in conditions mimicking the eye
Yao, H., Afanasiev, A., Lähdesmäki, I., & Parviz, B. A. (2011) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2011.5734353 · Cited by 29 · see citing works
Self-citationMcGrath, M. J., Iwuoha, E. I., Diamond, D., et al. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99231-9 · Cited by 23 · see citing works
Study of the thermal stability of glucose oxidase in the presence of water‐soluble polymers
Godjevargova, T. I., Vasileva, N., & Letskovska, Z. (2003) · Journal of Applied Polymer Science · doi:10.1002/app.12845 · Cited by 17 · see citing works
Analysis of Human Tear Fluid Components, Inhibiting Protein Adhesion to Plastic Surfaces
Kuizenga, A., Haeringen, N. J. V., MEIJER, F., et al. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0121 · Cited by 15 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Asada G, Dong M, Lin T S, Newberg F, Pottie G and Kaiser W J 1998 Wireless integrated network sensors: low power systems on a chip IEEE Proc. 24th European Solid State Circuits Conf. pp 9-16
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350 · see citing works
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · see citing works
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · see citing works
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678 · see citing works
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535 · see citing works
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452 · see citing works
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315 · see citing works
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200 · see citing works
Wearable Biofuel Cells: A Review
Bandodkar, A. J., & Wang, J. (2016) · Electroanalysis · doi:10.1002/elan.201600019 · Cited by 193 · see citing works
Kownacka, A. E., Vegelyte, D., Joosse, M., Anton, N., Toebes, B. J., Lauko, J., Buzzacchera, I., Lipinska, K., Wilson, D. A., Geelhoed-Duijvestijn, N., et al. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b01429 · Cited by 164 · see citing works
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135 · see citing works
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71 · see citing works
- Authors
- Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A.
- Affiliations
- University of Washington (US)
- Corresponding author
- Parviz, B A
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2012-06-07
- Volume
- 22
- Issue
- 7
- Pages
- 075007
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2029714639
- Cited by
- 182
- References
- 29
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 11 · 2023: 14 · 2022: 15 · 2021: 27 · 2020: 19 · 2019: 25 · 2018: 18 · 2017: 14 · 2016: 13 · 2015: 8 · 2014: 3 · 2013: 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Micromechanics and Microengineering (publishedVersion)
- Funders
- National Science Foundation (0937710)
- University of Washington
- Division of Emerging Frontiers in Research and Innovation
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- smart contact lens, non-invasive glucose monitoring, tear glucose, glucose oxidase immobilization, electrochemical sensor, wireless data transmission, wireless power transfer, low-power readout circuit, antenna, protein fouling, sensor aging, temperature sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review