The DOI matches its Crossref record.
Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration
Abstract
The electrode response time and the measured concentrations during dynamic catecholamine changes were compared using constant potential amperometry and fast-scan cyclic voltammetry. The amperometric response to a rectangular pulse of catecholamine is more rectangular than the cyclic voltammetric response; however, the response times are very similar when, during cyclic voltammetry, the temporal lag due to adsorption and desorption of catecholamine to the electrode is removed by deconvolution. Deconvolution of cyclic voltammetry data was applied to stimulated dopamine release in vivo, allowing for modeling of release and uptake kinetics and to measure catecholamine release from single cells, resulting in better resolution of peaks from single vesicles. In vitro postcalibrations were performed to calculate concentrations of catecholamine measured with cyclic voltammetry and amperometry. The addition of 600 microM ascorbic acid to the postcalibration buffer, allowing a catalytic reaction to regenerate dopamine, resulted in similar calculated concentrations for stimulated release of dopamine using amperometry and cyclic voltammetry. Using deconvoluted cyclic voltammetry to remove the response time lag and adding ascorbic acid to the calibration buffer, the shape and concentration of dynamic catecholamine changes are very similar when measured with constant potential amperometry and cyclic voltammetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mesolimbic dopamine signals the value of work
Hamid, A. A., Pettibone, J. R., Mabrouk, O. S., Hetrick, V. L., Schmidt, R., Vander Weele, C. M., Kennedy, R. T., Aragona, B. J., & Berke, J. D. (2016) · Nature Neuroscience · doi:10.1038/nn.4173 · Cited by 824
Monitoring Rapid Chemical Communication in the Brain
Robinson, D. L., Hermans, A., Seipel, A. T., & Wightman, R. M. (2008) · Chemical Reviews · doi:10.1021/cr068081q · Cited by 669
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Detecting Subsecond Dopamine Release with Fast-Scan Cyclic Voltammetry in Vivo
Robinson, D. L., Venton, B. J., Heien, M. L. A. V., & Wightman, R. M. (2003) · Clinical Chemistry · doi:10.1373/49.10.1763 · Cited by 606
Self-citationNew trends in the electrochemical sensing of dopamine
Jackowska, K., & Krysinski, P. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6578-2 · Cited by 461
Metadata
- Authors
- Venton, B. J., Troyer, K. P., & Wightman, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-22
- Volume
- 74
- Issue
- 3
- Pages
- 539-546
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1986719333
- Cited by
- 174
- References
- 0
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration. https://app.cochat.ai/papers/10.1021/ac010819a
- The paper
- Venton, B. J., Troyer, K. P., & Wightman, R. M. (2002). Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration. Analytical Chemistry. https://doi.org/10.1021/ac010819a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.