Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Response Times of Carbon Fiber Microelectrodes to Dynamic Changes in Catecholamine Concentration

Venton, B. Jill, Troyer, Kevin P., Wightman, R. Mark·2002·Analytical Chemistry

Abstract

The electrode response time and the measured concentrations during dynamic catecholamine changes were compared using constant potential amperometry and fast-scan cyclic voltammetry. The amperometric response to a rectangular pulse of catecholamine is more rectangular than the cyclic voltammetric response; however, the response times are very similar when, during cyclic voltammetry, the temporal lag due to adsorption and desorption of catecholamine to the electrode is removed by deconvolution. Deconvolution of cyclic voltammetry data was applied to stimulated dopamine release in vivo, allowing for modeling of release and uptake kinetics and to measure catecholamine release from single cells, resulting in better resolution of peaks from single vesicles. In vitro postcalibrations were performed to calculate concentrations of catecholamine measured with cyclic voltammetry and amperometry. The addition of 600 microM ascorbic acid to the postcalibration buffer, allowing a catalytic reaction to regenerate dopamine, resulted in similar calculated concentrations for stimulated release of dopamine using amperometry and cyclic voltammetry. Using deconvoluted cyclic voltammetry to remove the response time lag and adding ascorbic acid to the calibration buffer, the shape and concentration of dynamic catecholamine changes are very similar when measured with constant potential amperometry and cyclic voltammetry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac010819a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Venton, B. J., Troyer, K. P., & Wightman, R. M.
Venue
Analytical Chemistry
Published
2001-12-22
Volume
74
Issue
3
Pages
539-546
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1986719333
Cited by
174
References
0
FWCI
5.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.