The DOI matches its Crossref record.
A Method to Construct a Third-Generation Horseradish Peroxidase Biosensor: Self-Assembling Gold Nanoparticles to Three-Dimensional Sol−Gel Network
Abstract
A novel method for fabrication of horseradish peroxidase biosensor has been developed by self-assembling gold nanoparticles to a thiol-containing sol-gel network. A cleaned gold electrode was first immersed in a hydrolyzed (3-mercaptopropyl)-trimethoxysilane (MPS) sol-gel solution to assemble three-dimensional silica gel, and then gold nanoparticles were chemisorbed onto the thiol groups of the sol-gel network. Finally, horseradish peroxidase (HRP) was adsorbed onto the surface of the gold nanoparticles. The distribution of gold nanoparticles and HRP was examined by atomic force microscopy (AFM). The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The performance and factors influencing the performance of the resulting biosensor were studied in detail. The resulting biosensor exhibited fast amperometric response (2.5 s) to H2O2. The detection limit of the biosensor was 2.0 micromol L(-1), and the linear range was from 5.0 micromol L(-1) to 10.0 mmol L(-1). Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Gold nanoparticle-based electrochemical biosensors
Pingarrón, J. M., Yáñez-Sedeño, P., & González-Cortés, A. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.005 · Cited by 965
A Comprehensive Review on Function and Application of Plant Peroxidases
Pandey, V. P., Awasthi, M., Singh, S., Tiwari, S., & Dwivedi, U. N. (2017) · Biochemistry & Analytical Biochemistry · doi:10.4172/2161-1009.1000308 · Cited by 389
Potential applications of peroxidases
Hamid, M., & Khalil-ur-Rehman (2009) · Food Chemistry · doi:10.1016/j.foodchem.2009.02.035 · Cited by 312
Biotechnological applications of peroxidases
Regalado, C., García-Almendárez, B. E., & Duarte-Vázquez, M. A. (2004) · Phytochemistry Reviews · doi:10.1023/b:phyt.0000047797.81958.69 · Cited by 190
Bilal, M., Rasheed, T., Iqbal, H. M. N., & Yan, Y. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2018.06.274 · Cited by 184
Horseradish peroxidase (HRP) as a tool in green chemistry
Lopes, G. R., Pinto, D. C. G. A., & Silva, A. M. S. (2014) · RSC Adv. · doi:10.1039/c4ra06094f · Cited by 154
Metadata
- Authors
- Jia, J., Wang, B., Wu, A., Cheng, G., Li, Z., & Dong, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-03-28
- Volume
- 74
- Issue
- 9
- Pages
- 2217-2223
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047055772
- Cited by
- 653
- References
- 0
- FWCI
- 24.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.