The DOI matches its Crossref record.
Reference Potential Calibration and Voltammetry at Macrodisk Electrodes of Metallocene Derivatives in the Ionic Liquid [bmim][PF6]
Abstract
Reference potential scales are not generally available in ionic liquids. Consequently, comparison of data with those obtained in conventional solvent (electrolyte) media is not possible. The process [Co(Cp)2](+/0) (Co(Cp)2 = cobaltocene) has been studied at gold, glassy carbon and platinum macrodisk electrodes to test the feasibility of using this redox couple as a voltammetric reference standard in the ionic liquid 1-n-butyl-3-methylimidazolium hexafluorophosphate ([bmim][PF6]). A reversible, one-electron reduction process was observed, and the measured reversible potential versus a silver quasi-reference electrode was independent of the working electrode material, the concentration, and the scan rate. Ferrocene, the other traditionally used reference compound, is poorly soluble in this ionic liquid. However, the solution-phase voltammetry of ethylferrocene could be readily studied in [bmim][PF6], and a reversible oxidation process was observed. A reversible potential of +1285 +/- 5 mV versus the [Co(Cp)2](+/0) reference potential scale was obtained, and this value is comparable with that obtained in CH3CN (0.1 M Bu4NPF6) when referenced to the same potential scale. Ferrocene, decamethylferrocence, 1,1'-dimethylferrocene, 1,1'-diacetylferrocene, and ferrocenecarboxaldehyde were adhered to the working electrode surface and immersed in [bmim][PF6]. In each case, solid-state voltammetry provided well-defined, reversible one-electron oxidation processes that had the appearance of being diffusion controlled, with charge neutralization occurring via the ionic liquid. Reversible potentials of the solid-state processes referenced against the [Co(Cp)2](+/0) scale were similar to solution-phase values obtained in CH3CN (0.1 M Bu4NPF6).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids synthesis and applications: An overview
Singh, S. K., & Savoy, A. W. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.112038 · Cited by 1,233
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Zhao, Y., Ding, Y., Li, Y., Peng, L., Byon, H. R., Goodenough, J. B., & Yu, G. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00289c · Cited by 458
Use of Room Temperature Ionic Liquids in Gas Sensor Design
Buzzeo, M. C., Hardacre, C., & Compton, R. G. (2004) · Analytical Chemistry · doi:10.1021/ac040042w · Cited by 397
Ionic liquids in surface electrochemistry
Liu, H., Liu, Y., & Li, J. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b921469k · Cited by 372
Metadata
- Authors
- Hultgren, V. M., Mariotti, A. W. A., Bond, A. M., & Wedd, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-01
- Volume
- 74
- Issue
- 13
- Pages
- 3151-3156
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1967727210
- Cited by
- 159
- References
- 0
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference Potential Calibration and Voltammetry at Macrodisk Electrodes of Metallocene Derivatives in the Ionic Liquid [bmim][PF6]. https://app.cochat.ai/papers/10.1021/ac015729k
- The paper
- Hultgren, V. M., Mariotti, A. W. A., Bond, A. M., & Wedd, A. G. (2002). Reference Potential Calibration and Voltammetry at Macrodisk Electrodes of Metallocene Derivatives in the Ionic Liquid [bmim][PF6]. Analytical Chemistry. https://doi.org/10.1021/ac015729k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.