The DOI matches its Crossref record.
Reactive Polymer Coatings: A First Step toward Surface Engineering of Microfluidic Devices
Abstract
We report fabrication, characterization, and use of microfluidic analysis devices containing surface-immobilized cell-capturing molecules. Amino-terminated biotin ligands are immobilized onto the luminal surface of a microdevice and effectively support self-assembly of proteins, antibodies, and mammalian cells. For this purpose, chemical vapor deposition (CVD) polymerization is used to functionalize PDMS-made microfluidic devices with poly[para-xylylene carboxylic acid pentafluorophenolester-co-para-xylylene]. The resulting reactive coating shows excellent adhesion when deposited in thin films (approximately 100 nm, and the distribution of the pentafluorophenol ester groups is reasonably uniform within the microchannel inner surface, as examined by fluorescence microscopy. The utility of these devices for cell-based bioassays is demonstrated by monitoring the concentration-dependent effect of the disintegrin echistatin on cell adhesion. The described assay format could be relevant to clinical research in various fields, including angiogenesis research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Senaratne, W., Andruzzi, L., & Ober, C. K. (2005) · Biomacromolecules · doi:10.1021/bm050180a · Cited by 695
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Das, A., & Theato, P. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00291 · Cited by 483
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Microcontact Printing: Limitations and Achievements
Perl, A., Reinhoudt, D. N., & Huskens, J. (2009) · Advanced Materials · doi:10.1002/adma.200801864 · Cited by 447
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Chemical Vapor Deposition of Conformal, Functional, and Responsive Polymer Films
Alf, M. E., Asatekin, A., Barr, M. C., Baxamusa, S. H., Chelawat, H., Ozaydin‐Ince, G., Petruczok, C. D., Sreenivasan, R., Tenhaeff, W. E., Trujillo, N. J., et al. (2010) · Advanced Materials · doi:10.1002/adma.200902765 · Cited by 399
Synthesis of well‐defined polymeric activated esters
Theato, P. (2008) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.22994 · Cited by 287
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.061 · Cited by 147
Self-citation
Metadata
- Authors
- Lahann, J., Balcells, M., Lu, H., Rodon, T., Jensen, K. F., & Langer, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-02
- Volume
- 75
- Issue
- 9
- Pages
- 2117-2122
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1990788276
- Cited by
- 189
- References
- 0
- FWCI
- 14.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.