The insulation performance of reactive parylene films in implantable electronic devices
Open accessAbstract
Parylene-C (poly-chloro-p-xylylene) is an appropriate material for use in an implantable, microfabricated device. It is hydrophobic, conformally deposited, has a low dielectric constant, and superb biocompatibility. Yet for many bioelectrical applications, its poor wet adhesion may be an impassable shortcoming. This research contrasts parylene-C and poly(p-xylylene) functionalized with reactive group X (PPX-X) layers using long-term electrical soak and adhesion tests. The reactive parylene was made of complementary derivatives having aldehyde and aminomethyl side groups (PPX-CHO and PPX-CH2NH2 respectively). These functional groups have previously been shown to covalently react together after heating. Electrical testing was conducted in saline at 37 degrees C on interdigitated electrodes with either parylene-C or reactive parylene as the metal layer interface. Results showed that reactive parylene devices maintained the highest impedance. Heat-treated PPX-X device impedance was 800% greater at 10kHz and 70% greater at 1Hz relative to heated parylene-C controls after 60 days. Heat treatment proved to be critical for maintaining high impedance of both parylene-C and the reactive parylene. Adhesion measurements showed improved wet metal adhesion for PPX-X, which corresponds well with its excellent high frequency performance.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Previous studies of peripheral implants used for rodents have reported peak-to-peak signal amplitudes ranging from 100-900 μV in response to electrical stimuli.
“Previous studies of peripheral implants used for rodents have reported peak-to-peak signal amplitudes ranging from 100–900 μV in response to electrical stimuli [22–27].”
From A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve (2017) · cites this paper as [23]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A Nonlinear Least Squares Fit procedure for analysis of immittance data of electrochemical systems
Boukamp, B. A. (1986) · Solid State Ionics · doi:10.1016/0167-2738(86)90031-7 · Cited by 1,775 · see citing works
Grundmeier, G., Schmidt, W., & Stratmann, M. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00348-0 · Cited by 622 · see citing works
(2004) · Wiley eBooks · doi:10.1002/3527603964 · Cited by 512 · see citing works
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · see citing works
Self-citationEvaluation of MEMS materials of construction for implantable medical devices
Kotzar, G., Freas, M., Abel, P. B., Fleischman, A. J., Roy, S., Zorman, C. A., Moran, J. M., & Melzak, J. M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00007-8 · Cited by 440 · see citing works
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1× · see citing works
“Most notably, parylene-C has been successfully used as a coating in neural recording arrays [12,13].”
MethodLong-term implants of Parylene-C coated microelectrodes
Schmidt, E., Mcintosh, J. S., & Bak, M. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/bf02441836 · Cited by 216 · see citing works
Metal-polymer interfaces: Adhesion and x-ray photoemission studies
Burkstrand, J. M. (1981) · Journal of Applied Physics · doi:10.1063/1.329320 · Cited by 210 · see citing works
Capacitance, Inductance, and CrossTalk Analysis
Walker, C. S. (1990) · CERN Document Server (European Organization for Nuclear Research) · Cited by 199 · see citing works
Reactive Polymer Coatings: A First Step toward Surface Engineering of Microfluidic Devices
Lahann, J., Balcells, M., Lu, H., et al. (2003) · Analytical Chemistry · doi:10.1021/ac020557s · Cited by 189 · see citing works
Self-citationGleiter, R., & Hopf, H. (2004) · Medical Entomology and Zoology · Cited by 174 · see citing works
High density interconnects and flexible hybrid assemblies for active biomedical implants
Meyer, J.-U., Stieglitz, T., Scholz, O., Haberer, W., & Beutel, H. (2001) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.938305 · Cited by 145 · see citing works
Characterization of low-temperature wafer bonding using thin-film parylene
Kim, H., & Najafi, K. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859102 · Cited by 132 · see citing works
Ziegler, D., Suzuki, T., & Takeuchi, S. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.879681 · Cited by 119 · see citing works
Chemical vapour deposition polymerization of substituted [2.2]paracyclophanes
Lahann, J., Klee, D., & Höcker, H. (1998) · Macromolecular Rapid Communications · doi:10.1002/(sici)1521-3927(19980901)19:9 · Cited by 112 · see citing works
Self-citationSolventless Adhesive Bonding Using Reactive Polymer Coatings
Chen, H.-Y., McClelland, A., Chen, Z., & Lahann, J. (2008) · Analytical Chemistry · doi:10.1021/ac800341m · Cited by 97 · see citing works
Self-citationNandivada, H., Chen, H., & Lahann, J. (2005) · Macromolecular Rapid Communications · doi:10.1002/marc.200500449 · Cited by 70 · see citing works
Self-citationInterfacial factors in corrosion protection: an EIS study of model systems
Yasuda, H. K., Yu, Q., & Chen, M. (2001) · Progress in Organic Coatings · doi:10.1016/s0300-9440(01)00142-4 · Cited by 65 · see citing works
The determination of coating performance using electrochemical impedance spectroscopy
van Westing, E. P. M., Ferrari, G. M., & de Wit, J. H. W. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)85104-2 · Cited by 59 · see citing works
Effect of glow discharge treatment of substrates on parylene-substrate adhesion
Sharma, A. K., & Yasuda, H. (1982) · Journal of Vacuum Science and Technology · doi:10.1116/1.571880 · Cited by 47 · see citing works
Interface-Engineered Parylene C Coating for Corrosion Protection of Cold-Rolled Steel
Yasuda, H. K., Chun, B., Cho, D. L., Lin, T. J., Yang, D., & Antonelli, J. (1996) · CORROSION · doi:10.5006/1.3292110 · Cited by 40 · see citing works
REACTIVE POLYMER COATINGS FOR BIOMIMETIC SURFACE ENGINEERING
Lahann, J. (2006) · Chemical Engineering Communications · doi:10.1080/00986440500511619 · Cited by 40 · see citing works
Self-citationMicroelectronic packaging for retinal prostheses
Rodger, D. C., & Tai, Y.-C. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511500 · Cited by 35 · see citing works
Photon Processing in Microelectronics and Photonics III
Fieret, J., Herman, P. R., Okada, T., et al. (2002) · SPIE eBooks · Cited by 33 · see citing works
Surface micromachined leakage proof Parylene check valve
Xie, J., Yang, X., Wang, X.-Q., & Tai, Y.-C. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2001.906598 · Cited by 31 · see citing works
Akbarinezhad, E., & Faridi, H. R. (2008) · Surface Engineering · doi:10.1179/174329408x326524 · Cited by 30 · see citing works
Engineering the surface and interface of Parylene C coatings by low-temperature plasmas
Yu, Q., Deffeyes, J. E., & Yasuda, H. K. (2001) · Progress in Organic Coatings · doi:10.1016/s0300-9440(01)00137-0 · Cited by 29 · see citing works
Sadhir, R. K., James, W. J., Yasuda, H., et al. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90064-8 · Cited by 28 · see citing works
Integrated Flexible Ocular Coil for Power and Data Transfer in Retinal Prostheses
Li, W., Rodger, D. C., Weiland, J. D., Humayun, M. S., & Tai, Y. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616593 · Cited by 28 · see citing works
Flexible parylene-valved skin for adaptive flow control
Pornsin-Sirirak, N., Liger, M., Tai, Y., Ho, S., & Ho, C. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2002.984100 · Cited by 27 · see citing works
Yamagishi, F. G. (1991) · Thin Solid Films · doi:10.1016/0040-6090(91)90539-a · Cited by 26 · see citing works
Formation of metal–oxygen–polymer complexes on polystyrene with nickel and chromium
Burkstrand, J. M. (1979) · Journal of Vacuum Science and Technology · doi:10.1116/1.570163 · Cited by 25 · see citing works
Laser microjoining of dissimilar and biocompatible materials
Bauer, I., Russek, U. A., Herfurth, H., et al. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.530239 · Cited by 23 · see citing works
Recent advances in phosphorescent OLEDs for small‐ and large‐area‐display sizes
Weaver, M. S., Kwong, R. C., Adamovich, V. A., et al. (2006) · Journal of the Society for Information Display · doi:10.1889/1.2206108 · Cited by 23 · see citing works
Klee, D., Weiss, N., & Lahann, J. (2004) · doi:10.1002/3527603964.ch18 · Cited by 19 · see citing works
Self-citationUddin, M. A., Ho, W. F., & Chan, H. P. (2007) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-007-9118-7 · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389 · see citing works
Self-citationA review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205 · see citing works
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161 · see citing works
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137 · see citing works
Novel multi-sided, microelectrode arrays for implantable neural applications
Seymour, J. P., Langhals, N. B., Anderson, D. J., & Kipke, D. R. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9512-z · Cited by 95 · see citing works
Self-citationCaravaca, A. S., Tsaava, T., Goldman, L., Silverman, H., Riggott, G., Chavan, S. S., Bouton, C., Tracey, K. J., Desimone, R., Boyden, E. S., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7a42 · Cited by 57 · see citing works
Design and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4 · see citing works
- Authors
- Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Seymour, John P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 30
- Issue
- 31
- Pages
- 6158-6167
- ISSN
- 0142-9612 (ISSN-L)
- PMC
- PMC2748105
- OpenAlex
- W1969213762
- Cited by
- 147
- References
- 36
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 12 · 2023: 15 · 2022: 8 · 2021: 11 · 2020: 2 · 2019: 5 · 2018: 8 · 2017: 12 · 2016: 10 · 2015: 17 · 2014: 6 · 2013: 10 · 2012: 3
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Defense
- University of Michigan
- Multidisciplinary University Research Initiative
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030, T32EB005582)
- National Institute of Dental and Craniofacial Research (T32DE007057)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- Parylene C, poly(p-xylylene), implantable electronics, dielectric insulation, electrical impedance, wet adhesion, heat treatment, interdigitated electrodes, saline immersion, biocompatibility
- MeSH terms
- Biocompatible Materials, Electrochemistry, Models, Theoretical, Polymers, Xylenes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review