Cited by 147Neuroscience and Neural EngineeringPolymer Surface Interaction StudiesConducting polymers and applications

The insulation performance of reactive parylene films in implantable electronic devices

Open access
Seymour, John P., Elkasabi, Yaseen M., Chen, Hsien-Yeh, Lahann, Joerg, Kipke, Daryl R.·2009·Biomaterials

Abstract

Parylene-C (poly-chloro-p-xylylene) is an appropriate material for use in an implantable, microfabricated device. It is hydrophobic, conformally deposited, has a low dielectric constant, and superb biocompatibility. Yet for many bioelectrical applications, its poor wet adhesion may be an impassable shortcoming. This research contrasts parylene-C and poly(p-xylylene) functionalized with reactive group X (PPX-X) layers using long-term electrical soak and adhesion tests. The reactive parylene was made of complementary derivatives having aldehyde and aminomethyl side groups (PPX-CHO and PPX-CH2NH2 respectively). These functional groups have previously been shown to covalently react together after heating. Electrical testing was conducted in saline at 37 degrees C on interdigitated electrodes with either parylene-C or reactive parylene as the metal layer interface. Results showed that reactive parylene devices maintained the highest impedance. Heat-treated PPX-X device impedance was 800% greater at 10kHz and 70% greater at 1Hz relative to heated parylene-C controls after 60 days. Heat treatment proved to be critical for maintaining high impedance of both parylene-C and the reactive parylene. Adhesion measurements showed improved wet metal adhesion for PPX-X, which corresponds well with its excellent high frequency performance.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2009.07.061

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R.
Affiliations
University of Michigan (US)
Corresponding author
Seymour, John P.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2009-10
Volume
30
Issue
31
Pages
6158-6167
ISSN
0142-9612 (ISSN-L)
OpenAlex
W1969213762
Cited by
147
References
36
Citations by year
2026: 4 · 2025: 8 · 2024: 12 · 2023: 15 · 2022: 8 · 2021: 11 · 2020: 2 · 2019: 5 · 2018: 8 · 2017: 12 · 2016: 10 · 2015: 17 · 2014: 6 · 2013: 10 · 2012: 3
FWCI
2.49
Type
journal article
Language
en
Open access
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • U.S. Department of Defense
  • University of Michigan
  • Multidisciplinary University Research Initiative
  • National Institute of Biomedical Imaging and Bioengineering (P41EB002030, T32EB005582)
  • National Institute of Dental and Craniofacial Research (T32DE007057)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
Parylene C, poly(p-xylylene), implantable electronics, dielectric insulation, electrical impedance, wet adhesion, heat treatment, interdigitated electrodes, saline immersion, biocompatibility
MeSH terms
Biocompatible Materials, Electrochemistry, Models, Theoretical, Polymers, Xylenes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review