The DOI matches its Crossref record.
pH-Sensitive Holographic Sensors
Abstract
Holographic sensors for monitoring H+ (pH) have been fabricated from ionizable monomers incorporated into thin, polymeric, hydrogel films which were transformed into volume holograms using a diffusion method coupled with holographic recording, using a frequency doubled Nd:YAG laser (532 nm). Unlike other optical pH sensors, it is possible to tailor the operational replay wavelength of the holographic sensor by careful control of the exposure conditions. The holographic diffraction wavelength (color) of the holograms was used to characterize their shrinkage and swelling behavior as a function of pH in various media. The effects of hydrogel composition, ionic strength, temperature, and factors influencing reversibility and response time are evaluated. Optimized holographic pH sensors show milli-pH resolution. The pH-sensing range of the holograms can be controlled through variation of the nature of the ionizable co-monomer used in polymer film construction; a series of holographic sensors displaying visually perceptible, fully reversible color changes over different pH ranges are demonstrated. A poly(hydroxyethyl methacrylate-co-methacrylic acid) holographic sensor was shown to be able to quantify the change in H+ concentrations in real time in a sample of milk undergoing homolactic fermentation in the presence of Lactobacillus casei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bio-inspired variable structural color materials
Zhao, Y., Xie, Z., Gu, H., Zhu, C., & Gu, Z. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15267c · Cited by 935
Hydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Stimuli-responsive hydrogel thin films
Tokarev, I., & Minko, S. (2009) · Soft Matter · doi:10.1039/b813827c · Cited by 579
Metadata
- Authors
- Marshall, A. J., Blyth, J., Davidson, C. A. B., & Lowe, C. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-01
- Volume
- 75
- Issue
- 17
- Pages
- 4423-4431
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2032523604
- Cited by
- 176
- References
- 0
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH-Sensitive Holographic Sensors. https://app.cochat.ai/papers/10.1021/ac020730k
- The paper
- Marshall, A. J., Blyth, J., Davidson, C. A. B., & Lowe, C. R. (2003). pH-Sensitive Holographic Sensors. Analytical Chemistry. https://doi.org/10.1021/ac020730k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.