Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

pH-Sensitive Holographic Sensors

Marshall, Alexander J., Blyth, Jeff, Davidson, Colin A. B., Lowe, Christopher R.·2003·Analytical Chemistry

Abstract

Holographic sensors for monitoring H+ (pH) have been fabricated from ionizable monomers incorporated into thin, polymeric, hydrogel films which were transformed into volume holograms using a diffusion method coupled with holographic recording, using a frequency doubled Nd:YAG laser (532 nm). Unlike other optical pH sensors, it is possible to tailor the operational replay wavelength of the holographic sensor by careful control of the exposure conditions. The holographic diffraction wavelength (color) of the holograms was used to characterize their shrinkage and swelling behavior as a function of pH in various media. The effects of hydrogel composition, ionic strength, temperature, and factors influencing reversibility and response time are evaluated. Optimized holographic pH sensors show milli-pH resolution. The pH-sensing range of the holograms can be controlled through variation of the nature of the ionizable co-monomer used in polymer film construction; a series of holographic sensors displaying visually perceptible, fully reversible color changes over different pH ranges are demonstrated. A poly(hydroxyethyl methacrylate-co-methacrylic acid) holographic sensor was shown to be able to quantify the change in H+ concentrations in real time in a sample of milk undergoing homolactic fermentation in the presence of Lactobacillus casei.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac020730k

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Marshall, A. J., Blyth, J., Davidson, C. A. B., & Lowe, C. R.
Venue
Analytical Chemistry
Published
2003-08-01
Volume
75
Issue
17
Pages
4423-4431
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2032523604
Cited by
176
References
0
FWCI
8.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.