The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
An Integrated Microfabricated Cell Sorter
Abstract
We have developed an integrated microfabricated cell sorter using multilayer soft lithography. This integrated cell sorter is incorporated with various microfluidic functionalities, including peristaltic pumps, dampers, switch valves, and input and output wells, to perform cell sorting in a coordinated and automated fashion. The active volume of an actuated valve on this integrated cell sorter can be as small as 1 pL, and the volume of optical interrogation is approximately 100 fL. Different algorithms of cell manipulation, including cell trapping, were implemented in these devices. We have also demonstrated sorting and recovery of Escherichia coli cells on the chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationMicromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Self-citationMicrofabricating Conjugated Polymer Actuators
Jager, E. W. H., Smela, E., & Inganäs, O. (2000) · Science · doi:10.1126/science.290.5496.1540 · Cited by 962
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Dielectrophoretic Sorting of Particles and Cells in a Microsystem
Fiedler, S., Shirley, S. G., Schnelle, T., & Fuhr, G. (1998) · Analytical Chemistry · doi:10.1021/ac971063b · Cited by 432
Predatory Dinosaur Remains from Madagascar: Implications for the Cretaceous Biogeography of Gondwana
Sampson, S. D., Witmer, L. M., Forster, C. A., Krause, D. W., O'Connor, P. M., Dodson, P., & Ravoavy, F. (1998) · Science · doi:10.1126/science.280.5366.1048 · Cited by 334
High-Density Nanosecond Charge Trapping in Thin Films of the Photoconductor ZnODEP
Liu, C.-Y., Pan, H.-L., Fox, M. A., & Bard, A. J. (1993) · Science · doi:10.1126/science.261.5123.897 · Cited by 274
Chain Mobility in the Amorphous Region of Nylon 6 Observed under Active Uniaxial Deformation
Loo, L. S., Cohen, R. E., & Gleason, K. K. (2000) · Science · doi:10.1126/science.288.5463.116 · Cited by 229
Measurement of kinase activation in single mammalian cells
Meredith, G. D., Sims, C. E., Soughayer, J. S., & Allbritton, N. L. (2000) · Nature Biotechnology · doi:10.1038/73760 · Cited by 132
Replication and Compression of Surface Structures with Polydimethylsiloxane Elastomer
Lisensky, G. C., Campbell, D. J., Beckman, K. J., et al. (1999) · Journal of Chemical Education · doi:10.1021/ed076p537 · Cited by 118
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Self-citationEl-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Guck, J., Schinkinger, S., Lincoln, B., Wottawah, F., Ebert, S., Romeyke, M., Lenz, D., Erickson, H. M., Ananthakrishnan, R., Mitchell, D., et al. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.045476 · Cited by 1,417
Metadata
- Authors
- Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-04-27
- Volume
- 74
- Issue
- 11
- Pages
- 2451-2457
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2011650104
- Cited by
- 510
- References
- 11
- FWCI
- 25.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.