The DOI matches its Crossref record.
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Abstract
Micromachining technology was used to prepare chemical analysis systems on glass chips (1 centimeter by 2 centimeters or larger) that utilize electroosmotic pumping to drive fluid flow and electrophoretic separation to distinguish sample components. Capillaries 1 to 10 centimeters long etched in the glass (cross section, 10 micrometers by 30 micrometers) allow for capillary electrophoresis-based separations of amino acids with up to 75,000 theoretical plates in about 15 seconds, and separations of about 600 plates can be effected within 4 seconds. Sample treatment steps within a manifold of intersecting capillaries were demonstrated for a simple sample dilution process. Manipulation of the applied voltages controlled the directions of fluid flow within the manifold. The principles demonstrated in this study can be used to develop a miniaturized system for sample handling and separation with no moving parts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Combinatorial and Evolution-Based Methods in the Creation of Enantioselective Catalysts
Reetz, M. T. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010119)40:2<284::aid-anie284>3.0.co;2-n · Cited by 594
Optical and Interferometric Lithography - Nanotechnology Enablers
Brueck, S. R. J. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.853538 · Cited by 304
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202
Emotion-on-a-chip (EOC): Evolution of biochip technology to measure human emotion using body fluids
Lee, J.-H., Hwang, Y., Cheon, K.-A., & Jung, H.-I. (2012) · Medical Hypotheses · doi:10.1016/j.mehy.2012.09.002 · Cited by 20
Metadata
- Authors
- Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A.
- Venue
- Science
- Published
- 1993-08-13
- Volume
- 261
- Issue
- 5123
- Pages
- 895-897
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1972466773
- Cited by
- 1,800
- References
- 0
- FWCI
- 21.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip. https://app.cochat.ai/papers/10.1126/science.261.5123.895
- The paper
- Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993). Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip. Science. https://doi.org/10.1126/science.261.5123.895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.