Detection of Malaria Parasites in Blood by Laser Desorption Mass Spectrometry
Abstract
A novel method for the in vitro detection of the protozoan Plasmodium, the causative agent of malaria, has been developed. It comprises a protocol for cleanup of whole blood samples, followed by direct ultraviolet laser desorption (LD) time-of-flight mass spectrometry. Intense ion signals are observed from intact ferriprotoporphyrin IX (heme), sequestered by malaria parasites during their growth in human red blood cells. The LD mass spectrum of the heme is structure-specific, and the signal intensities are correlated with the sample parasitemia (number of parasites per unit volume of blood). Parasitemia levels on the order of 10 parasites/microL blood can be unambiguously detected by this method. Consideration of laser beam parameters (spot size, rastering across the sample surface) and actual sample consumption suggests that the detection limits can be further improved by at least an order of magnitude. The influence of experimental factors, such as desorbed ion polarity, laser exposure and fluence, sample size, and parasite growth stage, on the threshold for parasite detection is also addressed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hemozoin can be detected by polarized light, by fluorescent properties allowing quantification in tissue, and by laser desorption mass spectrometry.
“Hemozoin can be detected by polarized light [48], by the fluorescent properties of hemozoin which allows quantification in tissue [49], and by laser desorption mass spectrometry (LDMS) that identifies distinct spectral features [50].”
From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [50]
Cites
Human Malaria Parasites in Continuous Culture
Trager, W. F., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,887 · see citing works
Characterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 815 · see citing works
Self-citationHEMOGLOBIN METABOLISM IN THE MALARIA PARASITEPLASMODIUM FALCIPARUM
Francis, S. E., Sullivan, D. J., & Goldberg, A. D. E. (1997) · Annual Review of Microbiology · doi:10.1146/annurev.micro.51.1.97 · Cited by 782 · see citing works
Malaria : parasite biology, pathogenesis, and protection
Sherman, I. W. (1998) · ASM Press eBooks · Cited by 764 · see citing works
Pettigrew, J. D., & Konishi, M. (1976) · Science · doi:10.1126/science.948741 · Cited by 312 · see citing works
Krugliak, M., Zhang, J., & Ginsburg, H. (2002) · Molecular and Biochemical Parasitology · doi:10.1016/s0166-6851(01)00427-3 · Cited by 246 · see citing works
Laser ionization mass analysis
Vértes, Á., Gijbels, R., & Adams, F. C. (1993) · Cited by 238 · see citing works
A review of the applications to solids of the laser ion source in mass spectrometry
Conzemius, R. J., & Capellen, J. (1980) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(80)85040-6 · Cited by 205 · see citing works
van Baar, B. L. M. (2000) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(99)00036-4 · Cited by 197 · see citing works
Dechy‐Cabaret, O., Benoit‐Vical, F., Robert, A., & Meunier, B. (2000) · ChemBioChem · doi:10.1002/1439-7633(20001117)1:4 · Cited by 160 · see citing works
Nobel Lectures Physiology or Medicine 1901–1921
Munch, J. C. (1968) · Military Medicine · doi:10.1093/milmed/133.5.423b · Cited by 154 · see citing works
Zhang, J., Krugliak, M., & Ginsburg, H. (1999) · Molecular and Biochemical Parasitology · doi:10.1016/s0166-6851(99)00008-0 · Cited by 129 · see citing works
Wagner, R. W., Ciringh, Y., Clausen, C. A., et al. (1999) · Chemistry of Materials · doi:10.1021/cm9903529 · Cited by 101 · see citing works
Laser mass spectrometry: an overview of techniques, instruments and applications
Cotter, R. J. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)85648-2 · Cited by 89 · see citing works
Laser Desorption Mass Spectrometry of Synthetic Multiporphyrin Arrays
Fenyö, D., Chait, B. T., Johnson, T. E., et al. (1997) · Journal of Porphyrins and Phthalocyanines · doi:10.1002/(sici)1099-1409(199701)1:1 · Cited by 80 · see citing works
Square wave voltammetry at the mercury film electrode: theoretical treatment
Kounaves, S. P., O’Dea, J. J., Chandresekhar, P., et al. (1986) · Analytical Chemistry · doi:10.1021/ac00127a061 · Cited by 57 · see citing works
Laser-desorption Fourier transform mass spectrometry of synthetic porphyrins
Brown, R. S., & Wilkins, C. L. (1986) · Analytical Chemistry · doi:10.1021/ac00127a060 · Cited by 41 · see citing works
Laser desorption techniques of nonvolatile organic substances
Hillenkamp, F. (1982) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(82)80117-4 · Cited by 37 · see citing works
Westman, A., Demirev, P. A., Huth-Fehre, T. W., et al. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)03904-z · Cited by 32 · see citing works
Self-citationChemical Analysis of Cancer Therapy Photosensitizers by Two-Step Laser Mass Spectrometry
Zhan, Q., Voumard, P., & Zenobi, R. (1994) · Analytical Chemistry · doi:10.1021/ac00091a041 · Cited by 20 · see citing works
The Medicines for Malaria Venture
Hentschel, C. C. (2002) · Nature · doi:10.1038/415715a · Cited by 8 · see citing works
Laser desorption multiphoton ionization mass spectrometry
Weeding, T. L., Steenvoorden, R. J. J. M., Kistemaker, P. G., et al. (1991) · Journal of Analytical and Applied Pyrolysis · doi:10.1016/0165-2370(91)80061-c · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Diagnosing malaria in pregnancy: An update
Fried, M., Muehlenbachs, A., & Duffy, P. E. (2012) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.12.98 · Cited by 80 · see citing works
DETECTION OF PLASMODIUM FALCIPARUM IN PREGNANCY BY LASER DESORPTION MASS SPECTROMETRY
NYUNT, M., PISCIOTTA, J., FELDMAN, A. B., THUMA, P., SCHOLL, P. F., DEMIREV, P. A., LIN, J. S., SHI, L., KUMAR, N., & SULLIVAN, D. J. (2005) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2005.73.485 · Cited by 43 · see citing works
Self-citation
- Authors
- Demirev, P. A., Feldman, A. B., Kongkasuriyachai, D., Scholl, P., Sullivan, & Kumar, N.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Demirev, P. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-04
- Volume
- 74
- Issue
- 14
- Pages
- 3262-3266
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998301395
- Cited by
- 82
- References
- 22
- Citations by year
- 2024: 1 · 2023: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 4 · 2014: 2 · 2013: 4 · 2012: 7
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (M01RR000722, RR00722)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- malaria, Plasmodium, parasite detection, laser desorption mass spectrometry, time-of-flight mass spectrometry, ferriprotoporphyrin IX, heme, parasitemia, detection limit, laser fluence
- MeSH terms
- Animals, Erythrocytes, Hemin, Humans, Plasmodium falciparum, Molecular Structure, Malaria, Falciparum, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review