Cited by 82Mass Spectrometry Techniques and ApplicationsMalaria Research and ControlSpectroscopy Techniques in Biomedical and Chemical Research

Detection of Malaria Parasites in Blood by Laser Desorption Mass Spectrometry

Demirev, P. A., Feldman, A. B., Kongkasuriyachai, D., Scholl, P., Sullivan,, D., Kumar, N.·2002·Analytical Chemistry

Abstract

A novel method for the in vitro detection of the protozoan Plasmodium, the causative agent of malaria, has been developed. It comprises a protocol for cleanup of whole blood samples, followed by direct ultraviolet laser desorption (LD) time-of-flight mass spectrometry. Intense ion signals are observed from intact ferriprotoporphyrin IX (heme), sequestered by malaria parasites during their growth in human red blood cells. The LD mass spectrum of the heme is structure-specific, and the signal intensities are correlated with the sample parasitemia (number of parasites per unit volume of blood). Parasitemia levels on the order of 10 parasites/microL blood can be unambiguously detected by this method. Consideration of laser beam parameters (spot size, rastering across the sample surface) and actual sample consumption suggests that the detection limits can be further improved by at least an order of magnitude. The influence of experimental factors, such as desorbed ion polarity, laser exposure and fluence, sample size, and parasite growth stage, on the threshold for parasite detection is also addressed.

Integrity signals

Registry

Crossref · 10.1021/ac025621k

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hemozoin can be detected by polarized light, by fluorescent properties allowing quantification in tissue, and by laser desorption mass spectrometry.

    “Hemozoin can be detected by polarized light [48], by the fluorescent properties of hemozoin which allows quantification in tissue [49], and by laser desorption mass spectrometry (LDMS) that identifies distinct spectral features [50].”

    From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [50]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Demirev, P. A., Feldman, A. B., Kongkasuriyachai, D., Scholl, P., Sullivan, & Kumar, N.
Affiliations
Johns Hopkins University (US)
Corresponding author
Demirev, P. A.
Venue
Analytical Chemistry
Published
2002-06-04
Volume
74
Issue
14
Pages
3262-3266
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1998301395
Cited by
82
References
22
Citations by year
2024: 1 · 2023: 3 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 6 · 2015: 4 · 2014: 2 · 2013: 4 · 2012: 7
FWCI
3.23
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Center for Research Resources (M01RR000722, RR00722)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
malaria, Plasmodium, parasite detection, laser desorption mass spectrometry, time-of-flight mass spectrometry, ferriprotoporphyrin IX, heme, parasitemia, detection limit, laser fluence
MeSH terms
Animals, Erythrocytes, Hemin, Humans, Plasmodium falciparum, Molecular Structure, Malaria, Falciparum, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review