Separation of Neutral Saccharide Mixtures with Capillary Electrochromatography Using Hydrophilic Monolithic Columns
The DOI matches its Crossref record.
Abstract
While developing a combination of capillary electrochromatography (CEC) with tandem mass spectrometry (MS) for the benefit of characterizing complex oligosaccharide mixtures, we needed highly efficient CEC columns operating in an "MS-friendly" mode. We demonstrate here novel types of polar, monolithic CEC columns that separate effectively complex mixtures of saccharides with the use of mobile phases containing acetonitrile/dilute ammonium formate buffers. Using the positive-ion mode of detection for neutral saccharides, the detection conditions were optimized down to the low-femtomole sensitivities with the use of an ion trap mass spectrometer. This column technology provides a nearly universal system that can separate a wide range of carbohydrates: mono- and oligosaccharides with the intact reducing end, as well as saccharide alditols. Even the anomers formed due to mutarotation could be resolved with a high content of organic phase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrophilic interaction chromatography
Hemström, P., & Irgum, K. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600199 · Cited by 1,176
Stationary and mobile phases in hydrophilic interaction chromatography: a review
Jandera, P. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.02.047 · Cited by 707
Glycan labeling strategies and their use in identification and quantification
Ruhaak, L. R., Zauner, G., Huhn, C., Bruggink, C., Deelder, A. M., & Wuhrer, M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3532-z · Cited by 479
Separation efficiencies in hydrophilic interaction chromatography
Ikegami, T., Tomomatsu, K., Takubo, H., Horie, K., & Tanaka, N. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.075 · Cited by 419
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105
Metadata
- Authors
- Que, A. H., & Novotny, M. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-09-10
- Volume
- 74
- Issue
- 20
- Pages
- 5184-5191
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1969434417
- Cited by
- 89
- References
- 0
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of Neutral Saccharide Mixtures with Capillary Electrochromatography Using Hydrophilic Monolithic Columns. https://app.cochat.ai/papers/10.1021/ac025781w
- The paper
- Que, A. H., & Novotny, M. V. (2002). Separation of Neutral Saccharide Mixtures with Capillary Electrochromatography Using Hydrophilic Monolithic Columns. Analytical Chemistry. https://doi.org/10.1021/ac025781w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.