Capillary Liquid Chromatography/Electrospray Mass Spectrometry for Analysis of Steroid Sulfates in Biological Samples
The DOI matches its Crossref record.
Abstract
A new procedure for capillary liquid chromatography-electrospray (CLC-ES) mass spectrometry is described. Using this procedure, coupling of a CLC column to a low-flow-rate ES interface is made simple. A 5-cm precolumn and a 35-cm analytical column, both fused-silica capillaries with an i.d. of 100 microm and packed with 3-microm octadecylsilane-bonded material, are coupled in series to a sheathless ES emitter. One solvent splitter is positioned between the loop injector and the precolumn, and a second, between the precolumn and the analytical column. By opening and closing the splitters in the appropriate order, this arrangement permits the injection of 1-20 microL of sample solution with analyte focusing onto the top of the precolumn, followed by isocratic or gradient elution at a flow rate of 0.2-0.3 microL/min through the analytical column. The relative standard deviation of the retention times of reference compounds was <3.5% (n = 5). The potential of the system in metabolome analysis, in which numerous isomeric compounds will require identification, is illustrated by the application of the system to the analysis of steroid sulfates in plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maninger, N., Wolkowitz, O. M., Reus, V. I., Epel, E. S., & Mellon, S. H. (2009) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2008.11.002 · Cited by 769
Targeted Metabolomics for Biomarker Discovery
Griffiths, W. J., Koal, T., Wang, Y., Kohl, M., Enot, D. P., & Deigner, H. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905579 · Cited by 415
Self-citationDo Rego, J. L., Seong, J. Y., Burel, D., Leprince, J., Luu-The, V., Tsutsui, K., Tonon, M.-C., Pelletier, G., & Vaudry, H. (2009) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2009.05.006 · Cited by 357
Liere, P., Pianos, A., Eychenne, B., Cambourg, A., Liu, S., Griffiths, W., Schumacher, M., Sjövall, J., & Baulieu, E.-E. (2004) · Journal of Lipid Research · doi:10.1194/jlr.m400244-jlr200 · Cited by 118
Self-citationSánchez-Guijo, A., Oji, V., Hartmann, M. F., Traupe, H., & Wudy, S. A. (2015) · Journal of Lipid Research · doi:10.1194/jlr.d061499 · Cited by 73
Buiarelli, F., Coccioli, F., Merolle, M., Neri, B., & Terracciano, A. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.09.068 · Cited by 53
Metadata
- Authors
- Liu, S., Griffiths, W. J., & Sjövall, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-23
- Volume
- 75
- Issue
- 4
- Pages
- 791-797
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2066816517
- Cited by
- 35
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.