CoChat

Capillary Isoelectric Focusing-Based Multidimensional Concentration/Separation Platform for Proteome Analysis

Chen, Jinzhi, Balgley, Brian M., DeVoe, Donald L., Lee, Cheng S. · 2003 · Analytical Chemistry
Cited by 129

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An integrated proteome concentration/separation approach involving on-line combination of capillary isoelectric focusing (CIEF) with capillary reversed-phase liquid chromatography (CRPLC) is developed for providing significant analyte concentration and extremely high resolving power toward protein and peptide mixtures. Upon completion of analyte focusing, the self-sharpening effect greatly restricts analyte diffusion and contributes to analyte stacking in narrowly focused bands with a concentration factor of approximately 240. In addition to analyte focusing, CIEF as the first separation dimension resolves proteins/peptides on the basis of their differences in pI and offers greater resolving power than that achieved in strong cation exchange chromatography. The grouping of two highly resolving and completely orthogonal separation techniques of CIEF and CRPLC, together with analyte focusing and concentration, significantly enhances the dynamic range and sensitivity of conventional mass spectrometry toward the identification of low-abundance proteins. The CIEF-based multidimensional separation/concentration platform enables the identification of a greater number of yeast soluble proteins than methods presented in the literature, yet requires a protein loading of only 9.6 microg. This protein loading is 2-3 orders of magnitude lower than those employed by the reported non-gel-based proteome techniques. The distribution of a codon adaptation index value for identified yeast proteins approximates to that predicted for the entire yeast proteome and supports the capability of CIEF-based proteome separation technology for achieving comprehensive proteome analysis. By reducing the inner diameter of chromatography columns from 180 microm to 100 microm, the required protein loading is further decreased from 9.6 microg to 960 ng, illustrating the potential usage of this proteome technology for the analysis of protein profiles within small cell populations or limited tissue samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac034014+

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 129

Metadata

Authors
Chen, J., Balgley, B. M., DeVoe, D. L., & Lee, C. S.
Venue
Analytical Chemistry
Published
2003-05-10
Volume
75
Issue
13
Pages
3145-3152
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2000296168
Cited by
129
References
1
FWCI
6.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.