The DOI matches its Crossref record.
An Amperometric Detector Formed of Highly Dispersed Ni Nanoparticles Embedded in a Graphite-like Carbon Film Electrode for Sugar Determination
Abstract
We achieved improved detection limits for sugars by developing a novel thin film containing 0.8% highly dispersed Ni nanoparticles in disordered graphite-like carbon (Ni-NDC) as a detection electrode for high-performance liquid chromatography. The Ni-NDC film was prepared in one step by a simple radio frequency (rf) sputtering method at a temperature below 200 degrees C. We characterized the film by XPS, TEM, and AFM analysis and found that the average Ni nanoparticle size was 3 nm and that the film consisted of a mixture of Ni, NiO, Ni2O3, and Ni(OH)2. We studied the electrochemical detection of sugars using the 0.8% Ni-NDC film electrode. The film electrode had excellent electrocatalytic ability and good stability compared with a Ni-bulk electrode with regard to the electrooxidation of sugars. We employed the Ni-NDC film as an HPLC detection electrode. We achieved a good separation of four sugars (glucose, fructose, sucrose, lactose) at a relatively low constant detection potential (0.40 V vs Ag/AgCl) and a linearity of over 3 orders of magnitude. We obtained improved detection limits for the investigated sugars, namely, 20, 25, 50, and 37 nM for glucose, fructose, sucrose, and lactose, respectively. This is at least 1 order of magnitude lower than the detection limits obtained with a Ni-bulk electrode with the same measurement condition. The Ni-NDC film electrode also showed good reproducibility with a relative standard deviation of 1.75% for 40 consecutive injections of glucose in a flow system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
The use of nanoparticles in electroanalysis: a review
Welch, C. M., & Compton, R. G. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0230-3 · Cited by 759
Electrospun Co3O4 nanofibers for sensitive and selective glucose detection
Ding, Y., Wang, Y., Su, L., Bellagamba, M., Zhang, H., & Lei, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.050 · Cited by 707
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Liu, Y., Teng, H., Hou, H., & You, T. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.032 · Cited by 391
Self-citationJelinek, R., & Kolusheva, S. (2004) · Chemical Reviews · doi:10.1021/cr0300284 · Cited by 334
Zhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
Fabrication of a glucose sensor based on a novel nanocomposite electrode
Safavi, A., Maleki, N., & Farjami, E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.040 · Cited by 296
Miao, Y., Ouyang, L., Zhou, S., Xu, L., Yang, Z., Xiao, M., & Ouyang, R. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.008 · Cited by 290
Lu, L.-M., Li, H.-B., Qu, F., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.033 · Cited by 277
CuO nanowires based sensitive and selective non-enzymatic glucose detection
Zhang, Y., Liu, Y., Su, L., Zhang, Z., Huo, D., Hou, C., & Lei, Y. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.08.096 · Cited by 260
Electrochemical sensors based on metal and semiconductor nanoparticles
Wang, F., & Hu, S. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0136-4 · Cited by 255
Božiček, B. L., Hreščak, J., Kušter, M., Kovač, J., Naglič, I., Markoli, B., Batič, B. Š., Šala, M., Drev, S., Marinko, Ž., et al. (2024) · Journal of Materials Science · doi:10.1007/s10853-024-09710-5 · Cited by 23
Metadata
- Authors
- You, T., Niwa, O., Chen, Z., Hayashi, K., Tomita, M., & Hirono, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-05
- Volume
- 75
- Issue
- 19
- Pages
- 5191-5196
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2017421227
- Cited by
- 199
- References
- 0
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.