Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

Ratiometric Optical PEBBLE Nanosensors for Real-Time Magnesium Ion Concentrations Inside Viable Cells

Park, Edwin J., Brasuel, Murphy, Behrend, Caleb, Philbert, Martin A., Kopelman, Raoul·2003·Analytical Chemistry

Abstract

This paper presents the development and characterization of a highly selective magnesium fluorescent optical nanosensor, made possible by PEBBLE (probe encapsulated by biologically localized embedding) technology. A ratiometric sensor has been developed by co-immobilizing a dye that is sensitive to and highly selective for magnesium, with a reference dye in a matrix. The sensors are prepared via a microemulsion polymerization process, which entraps the sensing components inside a polymer matrix. The resultant spherical sensors are approximately 40 nm in diameter. The Coumarin 343 (C343) dye, which by itself does not enter the cell, when immobilized in a PEBBLE is used as the magnesium-selective agent that provides the high and necessary selectivity over other intracellular ions, such as Ca2+, Na+, and K+. The dynamic range of these sensors was 1-30 mM, with a linear range from 1 to 10 mM, with a response time of <4 s. In contrast to free dye, these nano-optodes are not perturbed by proteins. They are fully reversible and exhibit minimal leaching and photobleaching over extended periods of time. In vitro intracellular changes in Mg2+ concentration were monitored in C6 glioma cells, which remained viable after PEBBLE delivery via gene gun injection. The selectivity for Mg2+ along with the biocompatibility of the matrix provides a new and reliable tool for intracellular magnesium measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0342323

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Park, E. J., Brasuel, M., Behrend, C., Philbert, M. A., & Kopelman, R.
Venue
Analytical Chemistry
Published
2003-06-27
Volume
75
Issue
15
Pages
3784-3791
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2063343818
Cited by
200
References
0
FWCI
10.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ratiometric Optical PEBBLE Nanosensors for Real-Time Magnesium Ion Concentrations Inside Viable Cells. https://app.cochat.ai/papers/10.1021/ac0342323
The paper
Park, E. J., Brasuel, M., Behrend, C., Philbert, M. A., & Kopelman, R. (2003). Ratiometric Optical PEBBLE Nanosensors for Real-Time Magnesium Ion Concentrations Inside Viable Cells. Analytical Chemistry. https://doi.org/10.1021/ac0342323

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.