Whole Protein Dissociation in a Quadrupole Ion Trap: Identification of an a Priori Unknown Modified Protein
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A protein mixture derived from a whole cell lysate fraction of Saccharomyces cerevisiae, which contains roughly 19 proteins, has been analyzed to identify an a priori unknown modified protein using a quadrupole ion trap tandem mass spectrometer. Collection of the experimental data was facilitated by collision-induced dissociation and ion/ion proton-transfer reactions in multistage mass spectrometry procedures. Ion/ion reactions were used to manipulate charge states of both parent ions and product ions for the purpose of concentrating charge into the parent ion of interest and to reduce the product ion charge states for determination of product ion mass and abundance. The identification of the protein was achieved by matching the uninterpreted product ion spectrum against protein sequence databases with varying degrees of annotation, coupled with a scoring scheme weighted for the relative abundances of the experimentally observed product ions and the frequency of fragmentations occurring at preferential sites. The protein was identified to be an acetylated yeast heat shock protein, HS12_Yeast (11.6 kDa), with the initiating methionine residue removed. This constitutes the first example of the identification of an a priori unknown protein that is not present in an annotated protein database using a "top-down" approach with a quadrupole ion trap. This example illustrates the utility of relatively low cost instrumentation with modest mass analysis characteristics for the identification of modified proteins without recourse to enzymatic digestion. It also illustrates how experimental data can be used interactively with protein databases when the modified protein of interest is not initially present in the database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Self-citation
Cited by
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Recent Developments in Gas-Phase Ion/Ion Reactions for Analytical Mass Spectrometry
Foreman, D. J., & McLuckey, S. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05014 · Cited by 65
Self-citation
Metadata
- Authors
- Amunugama, R., Hogan, J. M., Newton, K. A., & McLuckey, S. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-01-03
- Volume
- 76
- Issue
- 3
- Pages
- 720-727
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2059053140
- Cited by
- 56
- References
- 2
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.