The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Glucose Biosensor Based on the Microcantilever
Abstract
Diagnosis and management of diabetes require quantitative and selective detection of blood glucose levels. We report a technique for micromechanical detection of biologically relevant glucose concentrations by immobilization of glucose oxidase (GOx) onto a microcantilever surface. Microfabricated cantilevers have traditionally found utility in atomic force microscope imaging. During the past decade, however, microcantilevers have been increasingly used as transducers in chemical-sensing systems. This paper describes the combination of this technology with enzyme specificity to construct a highly selective glucose biosensor. The enzyme-functionalized microcantilever undergoes bending due to a change in surface stress induced by the reaction between glucose in solution and the GOx immobilized on the cantilever surface. Experiments were carried out under flow conditions. The common interferences for glucose detection in other detection schemes have been tested and have shown to have no effect on the measurement of blood glucose level by this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Glucose oxidase: natural occurrence, function, properties and industrial applications
Wong, C. M., Wong, K. H., & Chen, X. D. (2008) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-008-1407-4 · Cited by 553
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Nanotechnology in clinical laboratory diagnostics
Jain, K. K. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.014 · Cited by 453
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Metadata
- Authors
- Pei, J., Tian, F., & Thundat, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-03
- Volume
- 76
- Issue
- 2
- Pages
- 292-297
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2004040188
- Cited by
- 284
- References
- 2
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.