Cited by 434Electrochemical sensors and biosensorsAnalytical Chemistry and SensorsAdvanced biosensing and bioanalysis techniques

Enzyme-Based Biosensors for in Vivo Measurements

Wilson, George S., Hu, Yibai·2000·Chemical Reviews

Abstract

ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTEnzyme-Based Biosensors for in Vivo MeasurementsGeorge S. Wilson and Yibai HuView Author Information Department of Chemistry and the Center for Neurobiology and Immunology Research, University of Kansas, Lawrence, Kansas 66045 Cite this: Chem. Rev. 2000, 100, 7, 2693–2704Publication Date (Web):June 3, 2000Publication History Received4 August 1999Published online3 June 2000Published inissue 1 July 2000https://pubs.acs.org/doi/10.1021/cr990003yhttps://doi.org/10.1021/cr990003yresearch-articleACS PublicationsCopyright © 2000 American Chemical SocietyRequest reuse permissionsArticle Views4436Altmetric-Citations348LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Carbohydrates,Electrodes,Oxygen,Peptides and proteins,Sensors Get e-Alerts

Integrity signals

Registry

Crossref · 10.1021/cr990003y

Cites

91 of 91 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • CGM supplies real-time data on glucose trends, magnitude, duration, and frequency of daily fluctuations.

    “Continuous glucose monitoring (CGM) provides real-time information on trends (i.e., whether the glucose levels are increasing or decreasing), magnitude, duration, and frequency of glucose fluctuations during the day.5–6”
  • Lag is also created by tissue responses to the sensor such as electrode fouling, biofouling, and foreign body encapsulation that impedes glucose diffusion.

    “Lag is also created by tissue responses to the sensor such as electrode fouling, biofouling, and the foreign body encapsulation that impedes glucose diffusion to the sensor.5–6”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wilson, G. S., & Hu, Y.
Affiliations
University of Kansas (US)
Venue
Chemical Reviews
Published
2000-06-03
Volume
100
Issue
7
Pages
2693-2704
ISSN
  • 0009-2665 (ISSN-L)
  • 1520-6890
OpenAlex
W2090187680
Cited by
434
References
91
Citations by year
2026: 11 · 2025: 16 · 2024: 18 · 2023: 15 · 2022: 12 · 2021: 17 · 2020: 10 · 2019: 13 · 2018: 18 · 2017: 12 · 2016: 21 · 2015: 22 · 2014: 18 · 2013: 30 · 2012: 15
FWCI
2.56
Type
journal article
Language
en
Open access
closed
Locations
  • Chemical Reviews (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institutes of Health
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
enzyme biosensor, in vivo measurement, in vivo biosensing, electrochemical biosensor, oxygen sensing, carbohydrate sensing, enzyme electrodes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review