The DOI matches its Crossref record.
Real-Time Measurements of Dissolved Oxygen Inside Live Cells by Organically Modified Silicate Fluorescent Nanosensors
Abstract
Optical PEBBLE (probes encapsulated by biologically localized embedding) nanosensors have been developed for dissolved oxygen using organically modified silicate (ormosil) nanoparticles as a matrix. The ormosil nanoparticles are prepared via a sol-gel-based process, which includes the formation of core particles with phenyltrimethoxysilane as a precursor followed by the formation of a coating layer with methyltrimethoxysilane as a precursor. The average diameter of the resultant particles is 120 nm. These sensors incorporate the oxygen-sensitive platinum porphyrin dye as an indicator and an oxygen-insensitive dye as a reference for ratiometric intensity measurement. Two pairs of indicator dye and reference dye, respectively, platinum(II) octaethylporphine and 3,3'-dioctadecyloxacarbocyanine perchlorate, and platinum(II) octaethylporphine ketone and octaethylporphine, were used. The sensors have excellent sensitivity with an overall quenching response of 97%, as well as excellent linearity of the Stern-Volmer plot (r(2) = 0.999) over the whole range of dissolved oxygen concentrations (0-43 ppm). In vitro intracellular changes of dissolved oxygen due to cell respiration were monitored, with gene gun injected PEBBLEs, in rat C6 glioma cells. A significant change was observed with a fluorescence ratio increase of up to 500% after 1 h, for nine different sets of cells, which corresponds to a 90% reduction in terms of dissolved oxygen concentration. These results clearly show the validity of the delivery method for intracellular studies of PEBBLE sensors, as well as the high sensitivity, which is needed to achieve real-time measurements of intracellular dissolved oxygen concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Lo, K. K.-W. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00211 · Cited by 566
Materials for fluorescence-based optical chemical sensors
Wolfbeis, O. S. (2005) · Journal of Materials Chemistry · doi:10.1039/b501536g · Cited by 486
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Nanoscale Metal–Organic Frameworks for Ratiometric Oxygen Sensing in Live Cells
Xu, R., Wang, Y., Duan, X., Lu, K., Micheroni, D., Hu, A., & Lin, W. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b13458 · Cited by 319
Toxicity of Luminescent Silica Nanoparticles to Living Cells
Jin, Y., Kannan, S., Wu, M., & Zhao, J. X. (2007) · Chemical Research in Toxicology · doi:10.1021/tx7001959 · Cited by 273
Hidalgo, G., Burns, A., Herz, E., Hay, A. G., Houston, P. L., Wiesner, U., & Lion, L. W. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.01220-09 · Cited by 127
Metadata
- Authors
- Koo, Y.-E. L., Cao, Y., Kopelman, R., Koo, S. M., Brasuel, M., & Philbert, M. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-02
- Volume
- 76
- Issue
- 9
- Pages
- 2498-2505
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2074623710
- Cited by
- 316
- References
- 0
- FWCI
- 16.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.