The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Nanoscale Metal–Organic Frameworks for Ratiometric Oxygen Sensing in Live Cells
Open accessAbstract
We report the design of a phosphorescence/fluorescence dual-emissive nanoscale metal-organic framework (NMOF), R-UiO, as an intracellular oxygen (O2) sensor. R-UiO contains a Pt(II)-porphyrin ligand as an O2-sensitive probe and a Rhodamine-B isothiocyanate ligand as an O2-insensitive reference probe. It exhibits good crystallinity, high stability, and excellent ratiometric luminescence response to O2 partial pressure. In vitro experiments confirmed the applicability of R-UiO as an intracellular O2 biosensor. This work is the first report of a NMOF-based intracellular oxygen sensor and should inspire the design of ratiometric NMOF sensors for other important analytes in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal–Organic Framework Materials as Chemical Sensors
Kreno, L. E., Leong, K., Farha, O. K., Allendorf, M., Van Duyne, R. P., & Hupp, J. T. (2012) · Chemical Reviews · doi:10.1021/cr200324t · Cited by 7,136
Hypoxia — a key regulatory factor in tumour growth
Harris, A. L. (2002) · Nature Reviews Cancer · doi:10.1038/nrc704 · Cited by 5,177
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Höckel, M., Schlenger, K., Aral, B., Mitze, M., Schäffer, U., & Vaupel, P. W. (1996) · PubMed · Cited by 1,727
BioMOFs: Metal–Organic Frameworks for Biological and Medical Applications
McKinlay, A. C., Morris, R. E., Horcajada, P., Férey, G., Gref, R., Couvreur, P., & Serre, C. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000048 · Cited by 1,256
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Direct measurement of local oxygen concentration in the bone marrow of live animals
Spencer, J. A., Ferraro, F., Roussakis, E., Klein, A., Wu, J., Runnels, J. M., Zaher, W., Mortensen, L. J., Alt, C., Turcotte, R., et al. (2014) · Nature · doi:10.1038/nature13034 · Cited by 1,167
A dual-emissive-materials design concept enables tumour hypoxia imaging
Zhang, G., Palmer, G. M., Dewhirst, M. W., & Fraser, C. L. (2009) · Nature Materials · doi:10.1038/nmat2509 · Cited by 1,150
Gatenby, R. A., Kessler, H. B., Rosenblum, J. S., Coia, L. R., Moldofsky, P. J., Hartz, W. H., & Broder, G. J. (1988) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(88)90002-8 · Cited by 798
Cited by
Luminescent sensors based on metal-organic frameworks
Zhang, Y., Yuan, S., Day, G., Wang, X., Yang, X., & Zhou, H.-C. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.007 · Cited by 1,255
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Ni, K., Lan, G., Chan, C., Quigley, B., Lu, K., Aung, T., Guo, N., La Riviere, P., Weichselbaum, R. R., & Lin, W. (2018) · Nature Communications · doi:10.1038/s41467-018-04703-w · Cited by 336
Self-citationMultifunctional metal–organic framework heterostructures for enhanced cancer therapy
Liu, J., Huang, J., Zhang, L., & Lei, J. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00178c · Cited by 285
Metadata
- Authors
- Xu, R., Wang, Y., Duan, X., Lu, K., Micheroni, D., Hu, A., & Lin, W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-02-16
- Volume
- 138
- Issue
- 7
- Pages
- 2158-2161
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2278059930
- Cited by
- 319
- References
- 36
- FWCI
- 18.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoscale Metal–Organic Frameworks for Ratiometric Oxygen Sensing in Live Cells. https://app.cochat.ai/papers/10.1021/jacs.5b13458
- The paper
- Xu, R., Wang, Y., Duan, X., Lu, K., Micheroni, D., Hu, A., & Lin, W. (2016). Nanoscale Metal–Organic Frameworks for Ratiometric Oxygen Sensing in Live Cells. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.5b13458
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.