The DOI matches its Crossref record.
Separation of Ions from Explosives in Differential Mobility Spectrometry by Vapor-Modified Drift Gas
Abstract
Differential mobility spectrometry (DMS) of nitro-organic explosives and related compounds exhibited the expected product ions of M- or M x NO2- from atmospheric pressure chemical ionization reactions in purified air at 100 degrees C. Peaks in the differential mobility spectra for these ions were confined to a narrow range of compensation voltages between -1 to +3 V which arose through a low dependence of mobility for the ions in electric fields at E/N values between 0 and 120 Td (1 Td = 10(-17) V cm2). The field dependence of ions, described as an alpha parameter, ranged from -0.005 to 0.02 at a separation field of 100 Td. The alpha parameter could be controlled through the addition of organic vapors into the drift gas and was increased to 0.08-0.24 with 1000 ppm of methylene chloride in the drift gas. This modification of the drift gas resulted in compensation voltages of +3 to +21 V for peaks. The improved separation of peaks was consistent with a model of ion characterization by DeltaK or Kl - Kh, where Kl is the mobility coefficient of ions clustered with vapor neutrals during the low-field portion of the separation field waveform and Kh is for the same core ion when heated and declustered during the high-field portion of waveform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Ion Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Self-citationKolakowski, B. M., & Mester, Z. (2007) · The Analyst · doi:10.1039/b706039d · Cited by 351
Ion dynamics in a trapped ion mobility spectrometer
Hernandez, D. R., DeBord, J. D., Ridgeway, M. E., Kaplan, D. A., Park, M. A., & Fernandez-Lima, F. (2014) · The Analyst · doi:10.1039/c3an02174b · Cited by 267
Metadata
- Authors
- Eiceman, G. A., Krylov, E. V., Krylova, N. S., Nazarov, E. G., & Miller, R. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-07-30
- Volume
- 76
- Issue
- 17
- Pages
- 4937-4944
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2085730038
- Cited by
- 186
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of Ions from Explosives in Differential Mobility Spectrometry by Vapor-Modified Drift Gas. https://app.cochat.ai/papers/10.1021/ac035502k
- The paper
- Eiceman, G. A., Krylov, E. V., Krylova, N. S., Nazarov, E. G., & Miller, R. A. (2004). Separation of Ions from Explosives in Differential Mobility Spectrometry by Vapor-Modified Drift Gas. Analytical Chemistry. https://doi.org/10.1021/ac035502k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.